| Field | Value |
|---|---|
| ENERGY STAR score | 90 (band A) |
| Site EUI | 57.4 kBtu/ft² |
| Source EUI | 78.4 kBtu/ft² |
| GHG emissions | 192 tCO₂e |
| GHG intensity | 3.4 kgCO₂e/ft² |
| Electricity | 171,903 kWh |
| Natural gas | 26,531 therms |
| Water use | 909 kgal |
| Gross floor area | 56,455 sq ft |
| Source record | dc:PM3983055:2024 |
The disclosure history
Year over year
| Year | Score | Δ | Site EUI | GHG emissions |
|---|---|---|---|---|
| 2024latest | 90 | -2 | 57.4 kBtu/ft² | 192 tCO₂e |
| 2023 | 92 | +4 | 51.7 kBtu/ft² | 173 tCO₂e |
| 2019 | 88 | +1 | 56.0 kBtu/ft² | 194 tCO₂e |
| 2018 | 87 | 58.4 kBtu/ft² | 206 tCO₂e | |
| 2017 | — | 50.7 kBtu/ft² | 187 tCO₂e | |
| 2016 | — | 51.7 kBtu/ft² | 187 tCO₂e | |
| 2015 | — | 54.5 kBtu/ft² | 217 tCO₂e | |
| 2014 | — | 59.6 kBtu/ft² | 235 tCO₂e | |
| 2013 | — | 50.5 kBtu/ft² | 204 tCO₂e |
Compliance context
Clean and Affordable Energy Act / BEPS
DC's Building Energy Performance Standards (BEPS) require buildings below the performance standard to improve on 5-year compliance cycles, with penalties for buildings that fail to meet their pathway.
Ownership
PROVINCE OF ST AUGUSTINE OF ORDER CAPUCHIN
Own or manage this building? Claim it to correct the record and get compliance alerts.
Location
- Address
- 4121 Harewood Rd., NE
- City
- Washington, DC
- State
- District of Columbia
- ZIP
- 20017
- Coordinates
- 38.94041, -77.00218
Within ~1 km
Nearby benchmarked buildings
Mixed Use Property · 2,360,328 sq ft
- Multiple Buildings #1score —
College/University · 804,605 sq ft
- Providence Hospital - DCscore 31
Hospital (General Medical & Surgical) · 614,191 sq ft
Worship Facility · 226,301 sq ft
- Carroll Manor Nursing and Rehabscore 61
Senior Living Community · 196,500 sq ft
- Columbus School of Lawscore —
College/University · 188,412 sq ft
See also: most efficient in Washington, DC · biggest emitters
Frequently asked questions
What is Capuchin College's energy grade?
Capuchin College scores 90 out of 100 on ENERGY STAR — band A (High performer (85–100)) — in its 2024 Washington, DC disclosure. Scores are national percentiles against similar buildings; 75+ qualifies for ENERGY STAR certification.
How much energy does Capuchin College use?
Its 2024 site energy-use intensity was 57.4 kBtu/ft² (78.4 kBtu/ft² source) across 56,455 sq ft, including 171,903 kWh of electricity and 26,531 therms of natural gas.
What are Capuchin College's carbon emissions?
Capuchin College reported 192 tCO₂e of greenhouse-gas emissions (3.4 kgCO₂e/ft²) for 2024. DC's Building Energy Performance Standards (BEPS) require buildings below the performance standard to improve on 5-year compliance cycles, with penalties for buildings that fail to meet their pathway.
Dataset updated . Source: Building Energy Benchmarking disclosure, record dc:PM3983055:2024.