The Heights I
Multifamily Housing in Washington, DC, DC · 400 Taylor St NE · 20017
Clean and Affordable Energy Act / BEPS · reporting year 2017
Benchmarking record
| Field | Value |
|---|---|
| ENERGY STAR score | 29 (band D) |
| Site EUI | 104.6 kBtu/ft² |
| Source EUI | 134.9 kBtu/ft² |
| GHG emissions | 966 tCO₂e |
| GHG intensity | 6.2 kgCO₂e/ft² |
| Electricity | 543,650 kWh |
| Natural gas | 143,077 therms |
| Water use | 4,611 kgal |
| Gross floor area | 154,532 sq ft |
| Source record | dc:PM3760910:2017 |
The disclosure history
Year over year
| Year | Score | Δ | Site EUI | GHG emissions |
|---|---|---|---|---|
| 2017latest | 29 | -15 | 104.6 kBtu/ft² | 966 tCO₂e |
| 2016 | 44 | +1 | 98.0 kBtu/ft² | 918 tCO₂e |
| 2015 | 43 | +3 | 95.7 kBtu/ft² | 955 tCO₂e |
| 2014 | 40 | +39 | 96.3 kBtu/ft² | 963 tCO₂e |
| 2013 | 1 | 134.1 kBtu/ft² | 1,515 tCO₂e | |
| 2012 | — | 2.3 kBtu/ft² | 46 tCO₂e |
Compliance context
Clean and Affordable Energy Act / BEPS
DC's Building Energy Performance Standards (BEPS) require buildings below the performance standard to improve on 5-year compliance cycles, with penalties for buildings that fail to meet their pathway.
Ownership
HEIGHTS LP
Own or manage this building? Claim it to correct the record and get compliance alerts.
Location
- Address
- 400 Taylor St NE
- City
- Washington, DC
- State
- District of Columbia
- ZIP
- 20017
- Coordinates
- 38.94262, -77.00130
Within ~1 km
Nearby benchmarked buildings
- Providence Hospital - DCscore 31
Hospital (General Medical & Surgical) · 614,191 sq ft
- Carroll Manor Nursing and Rehabscore 61
Senior Living Community · 196,500 sq ft
- Jeanne Jugan Residencescore 72
Senior Living Community · 181,896 sq ft
- Heights IIscore —
Multifamily Housing · 181,328 sq ft
- Brookland Ridge II (br405)score 61
Multifamily Housing · 177,243 sq ft
- Caroll Manorscore —
Outpatient Rehabilitation/Physical Therapy · 169,000 sq ft
See also: most efficient in Washington, DC · biggest emitters
Frequently asked questions
What is The Heights I's energy grade?
The Heights I scores 29 out of 100 on ENERGY STAR — band D (Lowest band (1–54)) — in its 2017 Washington, DC disclosure. Scores are national percentiles against similar buildings; 75+ qualifies for ENERGY STAR certification.
How much energy does The Heights I use?
Its 2017 site energy-use intensity was 104.6 kBtu/ft² (134.9 kBtu/ft² source) across 154,532 sq ft, including 543,650 kWh of electricity and 143,077 therms of natural gas.
What are The Heights I's carbon emissions?
The Heights I reported 966 tCO₂e of greenhouse-gas emissions (6.2 kgCO₂e/ft²) for 2017. DC's Building Energy Performance Standards (BEPS) require buildings below the performance standard to improve on 5-year compliance cycles, with penalties for buildings that fail to meet their pathway.
Dataset updated . Source: Building Energy Benchmarking disclosure, record dc:PM3760910:2017.