Berkeley Bowl
Commercial in Berkeley, CA · 2020 OREGON ST
At a glance
Berkeley Bowl is a 44,000-square-foot commercial building at 2020 OREGON ST in Berkeley, California. In its 2025 Berkeley benchmarking disclosure it reported an ENERGY STAR score of 90 out of 100 (grade A) and a site energy-use intensity of 205.4 kBtu/ft². That score is higher than 57% of the 84 scored commercial buildings in Berkeley.
BESO (BMC Chapter 19.81) · reporting year 2025
Benchmarking record
| Field | Value |
|---|---|
| ENERGY STAR score | 90 (band A) |
| Site EUI | 205.4 kBtu/ft² |
| Source EUI | 467.1 kBtu/ft² |
| GHG emissions | — |
| GHG intensity | — |
| Electricity | 1,852,523 kWh |
| Natural gas | 27,176 therms |
| Gross floor area | 44,000 sq ft |
| Source record | berkeley:1500:2025 |
The disclosure history
Year over year
| Year | Score | Δ | Site EUI | GHG emissions |
|---|---|---|---|---|
| 2025latest | 90 | -2 | 205.4 kBtu/ft² | — |
| 2024 | 92 | -2 | 194.5 kBtu/ft² | — |
| 2023 | 94 | -2 | 182.2 kBtu/ft² | — |
| 2022 | 96 | 160.7 kBtu/ft² | — |
Compliance context
BESO (BMC Chapter 19.81)
Berkeley's BESO requires annual benchmarking for commercial and multifamily buildings of 15,000 sq ft or more, with energy assessments at time of listing and every five years for buildings of 25,000 sq ft or more.
Ownership
No owning organisation shown. Names of private individuals in the disclosure are not published here.
Own or manage this building? Claim it to correct the record and get compliance alerts.
Location
- Address
- 2020 OREGON ST
- City
- Berkeley
- State
- California
Within ~1 km
Nearby benchmarked buildings
This source publishes no coordinates, so nearby buildings can't be resolved yet.
See also: most efficient in Berkeley · biggest emitters
How does Berkeley Bowl compare with other commercial buildings in Berkeley?
The latest disclosures cover 150 commercial buildings in Berkeley, out of 440 buildings citywide. Berkeley Bowl's ENERGY STAR score of 90 compares with an average of 77 across the 84 that report a score; it scores higher than 57% of them and lower than 37%. Its site EUI of 205.4 kBtu/ft² is about 323% above the average of 48.6 kBtu/ft² — it uses more energy per square foot than the typical building in that group.
At 44,000 sq ft, it is about 13% below the average floor area of 50,513 sq ft for those buildings. Across all 24 jurisdictions BuildingCensus covers, the 2,307 commercial buildings average an ENERGY STAR score of 76 and a site EUI of 51.3 kBtu/ft².
How has Berkeley Bowl's energy performance changed over time?
BuildingCensus holds 4 Berkeley disclosures for Berkeley Bowl, covering report years 2022–2025. Its ENERGY STAR score went from 96 in 2022 to 90 in 2025 (-6 points); its best year on file was 2022, at 96. Site EUI moved from 160.7 kBtu/ft² (2022) to 205.4 kBtu/ft² (2025), an 28% increase.
What does an ENERGY STAR score of 90 mean?
ENERGY STAR scores run from 1 to 100 and are computed by the EPA's Portfolio Manager as a percentile against similar buildings nationwide, adjusted for climate, size and use: a score of 90 means the building performs better than about 90% of its national peers. BuildingCensus bands the score into report-card grades; 90 falls in band A — high performer (85–100). Scores of 75 or higher meet the threshold for ENERGY STAR certification; certification itself is a separate, verified application that the disclosure does not record. In Berkeley, 82% of scored buildings are at 75 or above.
Site energy-use intensity (EUI) is the energy a building uses on site in a year divided by its floor area, in thousand Btu per square foot — lower is more efficient. Berkeley Bowl's 205.4 kBtu/ft² across 44,000 sq ft works out to about 9 billion Btu (2,649 MWh-equivalent) in 2025. Its source EUI of 467.1 kBtu/ft² also counts the energy lost generating and delivering that power, which is why it is higher. The disclosure also reports 1,852,523 kWh of electricity and 27,176 therms of natural gas for the year.
Which law requires Berkeley Bowl to report its energy use?
Berkeley Bowl reports under BESO (BMC Chapter 19.81), the legal basis of Berkeley's Building Emissions Saving Ordinance, which publishes each covered building's annual benchmarking results. The record shown here is the report-year 2025 disclosure (source record berkeley:1500:2025). Berkeley's BESO requires annual benchmarking for commercial and multifamily buildings of 15,000 sq ft or more, with energy assessments at time of listing and every five years for buildings of 25,000 sq ft or more.
More commercial buildings in Berkeley
- Tioga Bldg· 43,268 sq ft · EUI 18.8 kBtu/ft²
- Transfer Station Offices· 42,869 sq ft · EUI 29.6 kBtu/ft²
- 2407 DANA ST· 42,707 sq ft · EUI 41.5 kBtu/ft²
- Dharma College· 42,098 sq ft · score 100 (A)
- Parker Plaza (North)· 42,043 sq ft · score 99 (A)
- 2235 Sacramento St· 40,261 sq ft · score 84 (B)
- Commercial buildings in Berkeley· 150 benchmarked
- All Berkeley benchmarked buildings· BESO (BMC Chapter 19.81)
- Most efficient large buildings in Berkeley
- Least efficient large buildings in Berkeley
- Biggest emitters in Berkeley
Frequently asked questions
What is Berkeley Bowl's energy grade?
Berkeley Bowl scores 90 out of 100 on ENERGY STAR — band A, high performer (85–100) — in its 2025 Berkeley disclosure. Scores are national percentiles against similar buildings; 75+ qualifies for ENERGY STAR certification.
How much energy does Berkeley Bowl use?
Its 2025 site energy-use intensity was 205.4 kBtu/ft² (467.1 kBtu/ft² source) across 44,000 sq ft, including 1,852,523 kWh of electricity and 27,176 therms of natural gas.
What are Berkeley Bowl's carbon emissions?
No greenhouse-gas emissions figure was reported for 2025.
Where is Berkeley Bowl?
Berkeley Bowl is at 2020 OREGON ST, in Berkeley, California.
How big is Berkeley Bowl and when was it built?
Berkeley Bowl has 44,000 sq ft of gross floor area, as reported in its 2025 disclosure. It is classed as commercial.
Is Berkeley Bowl covered by BESO (BMC Chapter 19.81)?
Yes — it appears in the 2025 Building Emissions Saving Ordinance disclosure, which lists the buildings reporting under BESO (BMC Chapter 19.81).
Working with Berkeley building benchmarking records? Pro adds alerts, change history and CSV export ($49/mo); Enterprise adds full national files, the API and an MCP server for AI tools.
About this data
Source: Building Emissions Saving Ordinance (BESO (BMC Chapter 19.81)), as published October 2, 2026. See the methodology for how records are matched, cleaned and scored.
Cite as: BuildingCensus, “Berkeley Bowl, Berkeley, California — 2025 benchmarking disclosure”, https://buildingcensus.com/buildings/berkeley/berkeley-bowl-dd25c93a (data as of October 2, 2026).