St John Neumann
Senior Living Community in Philadelphia, PA · 10400 E Roosevelt Blvd · 19116
Phila. Code §9-3402 / Building Energy Performance Program · reporting year 2020
Benchmarking record
| Field | Value |
|---|---|
| ENERGY STAR score | 60 (band C) |
| Site EUI | 158.9 kBtu/ft² |
| Source EUI | 171.8 kBtu/ft² |
| GHG emissions | 719 tCO₂e |
| GHG intensity | — |
| Electricity | 69,994 kWh |
| Natural gas | 131,077 therms |
| Water use | 6,976 kgal |
| Gross floor area | 84,000 sq ft |
| Source record | philadelphia:4994315:2020 |
The disclosure history
Year over year
| Year | Score | Δ | Site EUI | GHG emissions |
|---|---|---|---|---|
| 2020latest | 60 | -5 | 158.9 kBtu/ft² | 719 tCO₂e |
| 2019 | 65 | 153.1 kBtu/ft² | 695 tCO₂e |
Compliance context
Phila. Code §9-3402 / Building Energy Performance Program
Philadelphia's Building Energy Performance Program requires buildings over 50,000 sq ft to benchmark and complete tune-ups, with fines for failure to report.
Ownership
No owner listed in the disclosure.
Own or manage this building? Claim it to correct the record and get compliance alerts.
Location
- Address
- 10400 E Roosevelt Blvd
- City
- Philadelphia
- State
- Pennsylvania
- ZIP
- 19116
- Coordinates
- 40.09874, -75.01172
Within ~1 km
Nearby benchmarked buildings
- Red Lion Shopping Centerscore —
Strip Mall · 1,044,206 sq ft
Strip Mall · 452,374 sq ft
- Monarch Global Brandsscore —
Manufacturing/Industrial Plant · 309,254 sq ft
- Norcom Road Owner LLCscore —
Manufacturing/Industrial Plant · 309,254 sq ft
- 2828 Charter Rd.score —
Mixed Use Property · 306,000 sq ft
- ROOSEVELT BOULEVARD ASSOC.score —
Other · 298,627 sq ft
See also: most efficient in Philadelphia · biggest emitters
Frequently asked questions
What is St John Neumann's energy grade?
St John Neumann scores 60 out of 100 on ENERGY STAR — band C (Below median (55–69)) — in its 2020 Philadelphia disclosure. Scores are national percentiles against similar buildings; 75+ qualifies for ENERGY STAR certification.
How much energy does St John Neumann use?
Its 2020 site energy-use intensity was 158.9 kBtu/ft² (171.8 kBtu/ft² source) across 84,000 sq ft, including 69,994 kWh of electricity and 131,077 therms of natural gas.
What are St John Neumann's carbon emissions?
St John Neumann reported 719 tCO₂e of greenhouse-gas emissions for 2020. Philadelphia's Building Energy Performance Program requires buildings over 50,000 sq ft to benchmark and complete tune-ups, with fines for failure to report.
Dataset updated . Source: Building Energy Benchmarking disclosure, record philadelphia:4994315:2020.