Axis Apts (Formerly Expo 62)
Multifamily Housing in Seattle, WA · 123 2ND AVE N · 98109
Seattle Energy Benchmarking Ordinance (SMC 22.920) · reporting year 2025
Benchmarking record
| Field | Value |
|---|---|
| ENERGY STAR score | 98 (band A) |
| Site EUI | 33.6 kBtu/ft² |
| Source EUI | 64.9 kBtu/ft² |
| GHG emissions | 124 tCO₂e |
| GHG intensity | 0.9 kgCO₂e/ft² |
| Electricity | 658,966 kWh |
| Natural gas | 22,241 therms |
| Gross floor area | 178,911 sq ft |
| Source record | seattle:21423:2025 |
The disclosure history
Year over year
| Year | Score | Δ | Site EUI | GHG emissions |
|---|---|---|---|---|
| 2025latest | 98 | +1 | 33.6 kBtu/ft² | 124 tCO₂e |
| 2024 | 97 | +2 | 35.2 kBtu/ft² | 140 tCO₂e |
| 2023 | 95 | +1 | 39.1 kBtu/ft² | 164 tCO₂e |
| 2022 | 94 | -3 | 41.3 kBtu/ft² | 178 tCO₂e |
| 2021 | 97 | +14 | 36.5 kBtu/ft² | 151 tCO₂e |
| 2020 | 83 | -14 | 54.6 kBtu/ft² | 170 tCO₂e |
| 2019 | 97 | -2 | 35.3 kBtu/ft² | 147 tCO₂e |
| 2018 | 99 | ±0 | 26.5 kBtu/ft² | 151 tCO₂e |
| 2017 | 99 | +2 | 27.3 kBtu/ft² | 151 tCO₂e |
| 2016 | 97 | +1 | 28.4 kBtu/ft² | 158 tCO₂e |
| 2015 | 96 | 28.1 kBtu/ft² | 149 tCO₂e |
Compliance context
Seattle Energy Benchmarking Ordinance (SMC 22.920)
Seattle's Building Emissions Performance Standard (adopted 2023) applies to buildings over 20,000 sq ft: benchmarking verification is due 2027–2030 and initial emissions targets 2031–2035, reaching net zero by 2041–2050, with fines for non-compliance.
Ownership
No owning organisation shown. Names of private individuals in the disclosure are not published here.
Own or manage this building? Claim it to correct the record and get compliance alerts.
Location
- Address
- 123 2ND AVE N
- City
- Seattle
- State
- Washington
- ZIP
- 98109
- Coordinates
- 47.61934, -122.35322
Within ~1 km
Nearby benchmarked buildings
- Climate Pledge Arenascore —
Indoor Arena · 932,000 sq ft
- Olympus Aptsscore 97
Multifamily Housing · 590,869 sq ft
Mixed Use Property · 524,610 sq ft
- Avalon Belltown Towersscore 72
Multifamily Housing · 397,034 sq ft
- Third And Broad Bldgscore 94
Office · 396,626 sq ft
- Armory - Seattle Centerscore —
Other · 396,085 sq ft
See also: most efficient in Seattle · biggest emitters
Frequently asked questions
What is Axis Apts (Formerly Expo 62)'s energy grade?
Axis Apts (Formerly Expo 62) scores 98 out of 100 on ENERGY STAR — band A (High performer (85–100)) — in its 2025 Seattle disclosure. Scores are national percentiles against similar buildings; 75+ qualifies for ENERGY STAR certification.
How much energy does Axis Apts (Formerly Expo 62) use?
Its 2025 site energy-use intensity was 33.6 kBtu/ft² (64.9 kBtu/ft² source) across 178,911 sq ft, including 658,966 kWh of electricity and 22,241 therms of natural gas.
What are Axis Apts (Formerly Expo 62)'s carbon emissions?
Axis Apts (Formerly Expo 62) reported 124 tCO₂e of greenhouse-gas emissions (0.9 kgCO₂e/ft²) for 2025. Seattle's Building Emissions Performance Standard (adopted 2023) applies to buildings over 20,000 sq ft: benchmarking verification is due 2027–2030 and initial emissions targets 2031–2035, reaching net zero by 2041–2050, with fines for non-compliance.
Working with Seattle building benchmarking records? Pro adds alerts, change history and CSV export ($49/mo); Enterprise adds full national files, the API and an MCP server for AI tools.
Dataset updated . Source: Building Energy Benchmarking disclosure, record seattle:21423:2025.