BuildingCensus
B

Building R

Office in Seattle, WA · 650 S ORCAS ST · 98108

ENERGY STAR score
80
band B · 2025
Site EUI
35.2
kBtu/ft²
GHG emissions
5
tCO₂e
GHG intensity
0.2
kgCO₂e/ft²
Floor area
28,304
sq ft
Year built
1970
vintage
◆ Loading map…
85–10070–8455–691–54
This entry + 6 nearby

Seattle Energy Benchmarking Ordinance (SMC 22.920) · reporting year 2025

Benchmarking record

FieldValue
ENERGY STAR score80 (band B)
Site EUI35.2 kBtu/ft²
Source EUI98.6 kBtu/ft²
GHG emissions5 tCO₂e
GHG intensity0.2 kgCO₂e/ft²
Electricity280,489 kWh
Gross floor area28,304 sq ft
Source recordseattle:20984:2025

The disclosure history

Year over year

YearScoreΔSite EUIGHG emissions
2025latest80+535.2 kBtu/ft²5 tCO₂e
202475+438.6 kBtu/ft²6 tCO₂e
202371+341.3 kBtu/ft²7 tCO₂e
202268+143.8 kBtu/ft²7 tCO₂e
202167-644.1 kBtu/ft²7 tCO₂e
202073+539.2 kBtu/ft²6 tCO₂e
201968+543.2 kBtu/ft²7 tCO₂e
201863+1146.4 kBtu/ft²7 tCO₂e
201752-1549.7 kBtu/ft²8 tCO₂e
201667-146.7 kBtu/ft²7 tCO₂e
20156846.4 kBtu/ft²7 tCO₂e

Compliance context

Seattle Energy Benchmarking Ordinance (SMC 22.920)

Seattle's Building Emissions Performance Standard (adopted 2023) applies to buildings over 20,000 sq ft: benchmarking verification is due 2027–2030 and initial emissions targets 2031–2035, reaching net zero by 2041–2050, with fines for non-compliance.

Program details →

Ownership

No owning organisation shown. Names of private individuals in the disclosure are not published here.

Own or manage this building? Claim it to correct the record and get compliance alerts.

Location

Address
650 S ORCAS ST
State
Washington
ZIP
98108
Coordinates
47.55196, -122.32518

Within ~1 km

Nearby benchmarked buildings

See also: most efficient in Seattle · biggest emitters

Frequently asked questions

What is Building R's energy grade?

Building R scores 80 out of 100 on ENERGY STAR — band B (Above median (70–84)) — in its 2025 Seattle disclosure. Scores are national percentiles against similar buildings; 75+ qualifies for ENERGY STAR certification.

How much energy does Building R use?

Its 2025 site energy-use intensity was 35.2 kBtu/ft² (98.6 kBtu/ft² source) across 28,304 sq ft, including 280,489 kWh of electricity.

What are Building R's carbon emissions?

Building R reported 5 tCO₂e of greenhouse-gas emissions (0.2 kgCO₂e/ft²) for 2025. Seattle's Building Emissions Performance Standard (adopted 2023) applies to buildings over 20,000 sq ft: benchmarking verification is due 2027–2030 and initial emissions targets 2031–2035, reaching net zero by 2041–2050, with fines for non-compliance.

Working with Seattle building benchmarking records? Pro adds alerts, change history and CSV export ($49/mo); Enterprise adds full national files, the API and an MCP server for AI tools.

Dataset updated . Source: Building Energy Benchmarking disclosure, record seattle:20984:2025.