At a glance
Even Hotels & Staybridge Suites is a 170,885-square-foot hotel at 527 FAIRVIEW AVE N in Seattle, Washington, built in 2018. In its 2025 Seattle benchmarking disclosure it reported an ENERGY STAR score of 87 out of 100 (grade A), a site energy-use intensity of 63.5 kBtu/ft² and 228 tCO₂e of greenhouse-gas emissions. That score is higher than 55% of the 78 scored hotel buildings in Seattle.
Seattle Energy Benchmarking Ordinance (SMC 22.920) · reporting year 2025
Benchmarking record
| Field | Value |
|---|---|
| ENERGY STAR score | 87 (band A) |
| Site EUI | 63.5 kBtu/ft² |
| Source EUI | 120.2 kBtu/ft² |
| GHG emissions | 228 tCO₂e |
| GHG intensity | 1.9 kgCO₂e/ft² |
| Electricity | 1,100,558 kWh |
| Natural gas | 40,318 therms |
| Gross floor area | 170,885 sq ft |
| Source record | seattle:50540:2025 |
The disclosure history
Year over year
| Year | Score | Δ | Site EUI | GHG emissions |
|---|---|---|---|---|
| 2025latest | 87 | 63.5 kBtu/ft² | 228 tCO₂e | |
| 2024 | — | — | — | |
| 2023 | — | — | — | |
| 2022 | 95 | -1 | 50.6 kBtu/ft² | 236 tCO₂e |
| 2021 | 96 | -4 | 47.8 kBtu/ft² | 208 tCO₂e |
| 2020 | 100 | +1 | 20.4 kBtu/ft² | 18 tCO₂e |
| 2019 | 99 | 26.7 kBtu/ft² | 23 tCO₂e |
Compliance context
Seattle Energy Benchmarking Ordinance (SMC 22.920)
Seattle's Building Emissions Performance Standard (adopted 2023) applies to buildings over 20,000 sq ft: benchmarking verification is due 2027–2030 and initial emissions targets 2031–2035, reaching net zero by 2041–2050, with fines for non-compliance.
Ownership
No owning organisation shown. Names of private individuals in the disclosure are not published here.
Own or manage this building? Claim it to correct the record and get compliance alerts.
Location
- Address
- 527 FAIRVIEW AVE N
- City
- Seattle
- State
- Washington
- ZIP
- 98109
- Coordinates
- 47.62403, -122.33485
Within ~1 km
Nearby benchmarked buildings
Office · 1,599,394 sq ft
- Onni South Lake Unionscore 77
Multifamily Housing · 1,546,084 sq ft
- Amazon Nitroscore 94
Office · 1,323,773 sq ft
- Troy Block (Amazon)score 88
Office · 1,261,155 sq ft
- Mirabella Retirement Communityscore 97
Senior Living Community · 724,148 sq ft
Laboratory · 716,128 sq ft
See also: most efficient in Seattle · biggest emitters
How does Even Hotels & Staybridge Suites compare with other hotel buildings in Seattle?
The latest disclosures cover 86 hotel buildings in Seattle, out of 3,871 buildings citywide. Even Hotels & Staybridge Suites's ENERGY STAR score of 87 compares with an average of 76 across the 78 that report a score; it scores higher than 55% of them and lower than 41%. Its site EUI of 63.5 kBtu/ft² is roughly in line with the average of 68.4 kBtu/ft² — it uses less energy per square foot than the typical building in that group. Its emissions intensity of 1.9 kgCO₂e/ft² is roughly in line with the group average of 2.0 kgCO₂e/ft².
At 170,885 sq ft, it is roughly in line with the average floor area of 165,912 sq ft for those buildings. It was built in 2018, 48 years later than the group's average year built (1971). Across all 24 jurisdictions BuildingCensus covers, the 3,812 hotel buildings average an ENERGY STAR score of 65 and a site EUI of 77.8 kBtu/ft².
How has Even Hotels & Staybridge Suites's energy performance changed over time?
BuildingCensus holds 7 Seattle disclosures for Even Hotels & Staybridge Suites, covering report years 2019–2025. Its ENERGY STAR score went from 99 in 2019 to 87 in 2025 (-12 points); its best year on file was 2020, at 100. Site EUI moved from 26.7 kBtu/ft² (2019) to 63.5 kBtu/ft² (2025), an 138% increase. Reported emissions went from 23 tCO₂e to 228 tCO₂e over the same span (up 890%).
What does an ENERGY STAR score of 87 mean?
ENERGY STAR scores run from 1 to 100 and are computed by the EPA's Portfolio Manager as a percentile against similar buildings nationwide, adjusted for climate, size and use: a score of 87 means the building performs better than about 87% of its national peers. BuildingCensus bands the score into report-card grades; 87 falls in band A — high performer (85–100). Scores of 75 or higher meet the threshold for ENERGY STAR certification; certification itself is a separate, verified application that the disclosure does not record. In Seattle, 69% of scored buildings are at 75 or above.
Site energy-use intensity (EUI) is the energy a building uses on site in a year divided by its floor area, in thousand Btu per square foot — lower is more efficient. Even Hotels & Staybridge Suites's 63.5 kBtu/ft² across 170,885 sq ft works out to about 10.9 billion Btu (3,180 MWh-equivalent) in 2025. Its source EUI of 120.2 kBtu/ft² also counts the energy lost generating and delivering that power, which is why it is higher. The disclosure also reports 1,100,558 kWh of electricity and 40,318 therms of natural gas for the year.
Which law requires Even Hotels & Staybridge Suites to report its energy use?
Even Hotels & Staybridge Suites reports under the Seattle Energy Benchmarking Ordinance (SMC 22.920), the legal basis of Seattle's Building Energy Benchmarking program, which publishes each covered building's annual benchmarking results. The record shown here is the report-year 2025 disclosure (source record seattle:50540:2025). Seattle's Building Emissions Performance Standard (adopted 2023) applies to buildings over 20,000 sq ft: benchmarking verification is due 2027–2030 and initial emissions targets 2031–2035, reaching net zero by 2041–2050, with fines for non-compliance.
More hotel buildings in Seattle
- Silver Cloud Inn Seattle· 168,449 sq ft · score 57 (C)
- Courtyard By Marriott - Pioneer Sq· 163,984 sq ft · score 75 (B)
- Hampton Inn & Suites· 162,222 sq ft
- Homewood Suites Hotel - Seattle· 155,602 sq ft · score 61 (C)
- Hotel Monaco· 153,163 sq ft · score 81 (B)
- Hampton Inn & Suites - Northgate· 150,596 sq ft · score 73 (B)
- Hotel buildings in Seattle· 86 benchmarked
- All Seattle benchmarked buildings· Seattle Energy Benchmarking Ordinance (SMC 22.920)
- Most efficient large buildings in Seattle
- Least efficient large buildings in Seattle
- Biggest emitters in Seattle
Frequently asked questions
What is Even Hotels & Staybridge Suites's energy grade?
Even Hotels & Staybridge Suites scores 87 out of 100 on ENERGY STAR — band A, high performer (85–100) — in its 2025 Seattle disclosure. Scores are national percentiles against similar buildings; 75+ qualifies for ENERGY STAR certification.
How much energy does Even Hotels & Staybridge Suites use?
Its 2025 site energy-use intensity was 63.5 kBtu/ft² (120.2 kBtu/ft² source) across 170,885 sq ft, including 1,100,558 kWh of electricity and 40,318 therms of natural gas.
What are Even Hotels & Staybridge Suites's carbon emissions?
Even Hotels & Staybridge Suites reported 228 tCO₂e of greenhouse-gas emissions (1.9 kgCO₂e/ft²) for 2025.
Where is Even Hotels & Staybridge Suites?
Even Hotels & Staybridge Suites is at 527 FAIRVIEW AVE N, in Seattle, Washington 98109. Its coordinates are 47.62403, -122.33485 (latitude, longitude), as published in the Building Energy Benchmarking file.
How big is Even Hotels & Staybridge Suites and when was it built?
Even Hotels & Staybridge Suites has 170,885 sq ft of gross floor area, as reported in its 2025 disclosure. The disclosure lists 2018 as its year built. It is classed as hotel.
Is Even Hotels & Staybridge Suites covered by the Seattle Energy Benchmarking Ordinance (SMC 22.920)?
Yes — it appears in the 2025 Building Energy Benchmarking disclosure, which lists the buildings reporting under the Seattle Energy Benchmarking Ordinance (SMC 22.920).
Working with Seattle building benchmarking records? Pro adds alerts, change history and CSV export ($49/mo); Enterprise adds full national files, the API and an MCP server for AI tools.
About this data
Source: Building Energy Benchmarking (Seattle Energy Benchmarking Ordinance (SMC 22.920)), as published October 2, 2026. See the methodology for how records are matched, cleaned and scored.
Cite as: BuildingCensus, “Even Hotels & Staybridge Suites, Seattle, Washington — 2025 benchmarking disclosure”, https://buildingcensus.com/buildings/seattle/even-hotels-staybridge-suites-66a6918c (data as of October 2, 2026).