Benchmarking record
| Field | Value |
|---|---|
| ENERGY STAR score | 83 (band B) |
| Site EUI | 30.7 kBtu/ft² |
| Source EUI | 85.9 kBtu/ft² |
| GHG emissions | 371 tCO₂e |
| GHG intensity | 2.7 kgCO₂e/ft² |
| Electricity | 1,239,016 kWh |
| Natural gas | 0 therms |
| Water use | 1,318 kgal |
| Gross floor area | 137,726 sq ft |
| Source record | dc:PM3857228:2024 |
The disclosure history
Year over year
| Year | Score | Δ | Site EUI | GHG emissions |
|---|---|---|---|---|
| 2024latest | 83 | ±0 | 30.7 kBtu/ft² | 371 tCO₂e |
| 2023 | 83 | -1 | 29.9 kBtu/ft² | 361 tCO₂e |
| 2022 | 84 | -6 | 31.7 kBtu/ft² | 384 tCO₂e |
| 2021 | 90 | -2 | 28.0 kBtu/ft² | 324 tCO₂e |
| 2020 | 92 | +9 | 27.3 kBtu/ft² | 324 tCO₂e |
| 2019 | 83 | +3 | 39.7 kBtu/ft² | 473 tCO₂e |
| 2018 | 80 | -5 | 42.7 kBtu/ft² | 508 tCO₂e |
| 2017 | 85 | +1 | 44.5 kBtu/ft² | 614 tCO₂e |
| 2016 | 84 | +8 | 46.9 kBtu/ft² | 669 tCO₂e |
| 2015 | 76 | -4 | 54.1 kBtu/ft² | 827 tCO₂e |
| 2014 | 80 | 50.6 kBtu/ft² | 774 tCO₂e | |
| 2013 | — | — | — |
Compliance context
Clean and Affordable Energy Act / BEPS
DC's Building Energy Performance Standards (BEPS) require buildings below the performance standard to improve on 5-year compliance cycles, with penalties for buildings that fail to meet their pathway.
Ownership
717 14TH STREET LLC
Own or manage this building? Claim it to correct the record and get compliance alerts.
Location
- Address
- 717 14th Street, NW
- City
- Washington, DC
- State
- District of Columbia
- ZIP
- 20005
- Coordinates
- 38.89881, -77.03169
Within ~1 km
Nearby benchmarked buildings
Hotel · 1,081,202 sq ft
Multifamily Housing · 1,075,449 sq ft
- Midtown Centerscore 91
Office · 911,093 sq ft
Office · 887,915 sq ft
Office · 876,744 sq ft
- Hyatt Grand Washington DCscore 67
Hotel · 819,138 sq ft
See also: most efficient in Washington, DC · biggest emitters
Frequently asked questions
What is 717 14th Street's energy grade?
717 14th Street scores 83 out of 100 on ENERGY STAR — band B (Above median (70–84)) — in its 2024 Washington, DC disclosure. Scores are national percentiles against similar buildings; 75+ qualifies for ENERGY STAR certification.
How much energy does 717 14th Street use?
Its 2024 site energy-use intensity was 30.7 kBtu/ft² (85.9 kBtu/ft² source) across 137,726 sq ft, including 1,239,016 kWh of electricity and 0 therms of natural gas.
What are 717 14th Street's carbon emissions?
717 14th Street reported 371 tCO₂e of greenhouse-gas emissions (2.7 kgCO₂e/ft²) for 2024. DC's Building Energy Performance Standards (BEPS) require buildings below the performance standard to improve on 5-year compliance cycles, with penalties for buildings that fail to meet their pathway.
Dataset updated . Source: Building Energy Benchmarking disclosure, record dc:PM3857228:2024.