Rhapsody Condominium
Multifamily Housing in Washington, DC, DC · 2120 Vermont Ave NW · 20001
Clean and Affordable Energy Act / BEPS · reporting year 2024
Benchmarking record
| Field | Value |
|---|---|
| ENERGY STAR score | 90 (band A) |
| Site EUI | 43.8 kBtu/ft² |
| Source EUI | 93.6 kBtu/ft² |
| GHG emissions | 513 tCO₂e |
| GHG intensity | 3.3 kgCO₂e/ft² |
| Electricity | 1,252,960 kWh |
| Natural gas | 25,927 therms |
| Water use | 7,152 kgal |
| Gross floor area | 156,917 sq ft |
| Source record | dc:PM14009905:2024 |
The disclosure history
Year over year
| Year | Score | Δ | Site EUI | GHG emissions |
|---|---|---|---|---|
| 2024latest | 90 | +2 | 43.8 kBtu/ft² | 513 tCO₂e |
| 2023 | 88 | ±0 | 42.7 kBtu/ft² | 504 tCO₂e |
| 2022 | 88 | +20 | 46.9 kBtu/ft² | 543 tCO₂e |
| 2021 | 68 | -2 | 58.6 kBtu/ft² | 562 tCO₂e |
| 2020 | 70 | +5 | 54.0 kBtu/ft² | 508 tCO₂e |
| 2019 | 65 | +8 | 61.1 kBtu/ft² | 588 tCO₂e |
| 2018 | 57 | 66.9 kBtu/ft² | 648 tCO₂e |
Compliance context
Clean and Affordable Energy Act / BEPS
DC's Building Energy Performance Standards (BEPS) require buildings below the performance standard to improve on 5-year compliance cycles, with penalties for buildings that fail to meet their pathway.
Ownership
THE RHAPSODY CONDOMINIUM
Own or manage this building? Claim it to correct the record and get compliance alerts.
Location
- Address
- 2120 Vermont Ave NW
- City
- Washington, DC
- State
- District of Columbia
- ZIP
- 20001
- Coordinates
- 38.91867, -77.02485
Within ~1 km
Nearby benchmarked buildings
College/University · 5,569,182 sq ft
College/University · 4,414,673 sq ft
- HU Sub Stationscore —
College/University (Campus-Level) · 3,543,436 sq ft
- Sub Station Buildingsscore —
College/University · 3,276,489 sq ft
- Howard University Hospital Complexscore 100
Hospital (General Medical & Surgical) · 712,485 sq ft
- Howard University Hospitalscore —
Hospital (General Medical & Surgical) · 647,500 sq ft
See also: most efficient in Washington, DC · biggest emitters
Frequently asked questions
What is Rhapsody Condominium's energy grade?
Rhapsody Condominium scores 90 out of 100 on ENERGY STAR — band A (High performer (85–100)) — in its 2024 Washington, DC disclosure. Scores are national percentiles against similar buildings; 75+ qualifies for ENERGY STAR certification.
How much energy does Rhapsody Condominium use?
Its 2024 site energy-use intensity was 43.8 kBtu/ft² (93.6 kBtu/ft² source) across 156,917 sq ft, including 1,252,960 kWh of electricity and 25,927 therms of natural gas.
What are Rhapsody Condominium's carbon emissions?
Rhapsody Condominium reported 513 tCO₂e of greenhouse-gas emissions (3.3 kgCO₂e/ft²) for 2024. DC's Building Energy Performance Standards (BEPS) require buildings below the performance standard to improve on 5-year compliance cycles, with penalties for buildings that fail to meet their pathway.
Dataset updated . Source: Building Energy Benchmarking disclosure, record dc:PM14009905:2024.