The Fennessy Loft
Multifamily Housing in Washington, DC, DC · 1209 13th St NW · 20005
Clean and Affordable Energy Act / BEPS · reporting year 2024
Benchmarking record
| Field | Value |
|---|---|
| ENERGY STAR score | 80 (band B) |
| Site EUI | 44.8 kBtu/ft² |
| Source EUI | 93.5 kBtu/ft² |
| GHG emissions | 148 tCO₂e |
| GHG intensity | 3.3 kgCO₂e/ft² |
| Electricity | 349,982 kWh |
| Natural gas | 8,211 therms |
| Water use | 1,225 kgal |
| Gross floor area | 44,998 sq ft |
| Source record | dc:PM19977738:2024 |
The disclosure history
Year over year
| Year | Score | Δ | Site EUI | GHG emissions |
|---|---|---|---|---|
| 2024latest | 80 | -3 | 44.8 kBtu/ft² | 148 tCO₂e |
| 2023 | 83 | +2 | 41.0 kBtu/ft² | 140 tCO₂e |
| 2022 | 81 | 44.2 kBtu/ft² | 151 tCO₂e |
Compliance context
Clean and Affordable Energy Act / BEPS
DC's Building Energy Performance Standards (BEPS) require buildings below the performance standard to improve on 5-year compliance cycles, with penalties for buildings that fail to meet their pathway.
Ownership
THE FENNESSY LOFTS CONDO
Own or manage this building? Claim it to correct the record and get compliance alerts.
Location
- Address
- 1209 13th St NW
- City
- Washington, DC
- State
- District of Columbia
- ZIP
- 20005
- Coordinates
- 38.90615, -77.02937
Within ~1 km
Nearby benchmarked buildings
Convention Center · 1,750,000 sq ft
Hotel · 1,081,202 sq ft
Multifamily Housing · 1,075,449 sq ft
- Midtown Centerscore 91
Office · 911,093 sq ft
- Hyatt Grand Washington DCscore 67
Hotel · 819,138 sq ft
- 1300 Buildingscore 95
Bank/Financial Institution · 803,167 sq ft
See also: most efficient in Washington, DC · biggest emitters
Frequently asked questions
What is The Fennessy Loft's energy grade?
The Fennessy Loft scores 80 out of 100 on ENERGY STAR — band B (Above median (70–84)) — in its 2024 Washington, DC disclosure. Scores are national percentiles against similar buildings; 75+ qualifies for ENERGY STAR certification.
How much energy does The Fennessy Loft use?
Its 2024 site energy-use intensity was 44.8 kBtu/ft² (93.5 kBtu/ft² source) across 44,998 sq ft, including 349,982 kWh of electricity and 8,211 therms of natural gas.
What are The Fennessy Loft's carbon emissions?
The Fennessy Loft reported 148 tCO₂e of greenhouse-gas emissions (3.3 kgCO₂e/ft²) for 2024. DC's Building Energy Performance Standards (BEPS) require buildings below the performance standard to improve on 5-year compliance cycles, with penalties for buildings that fail to meet their pathway.
Dataset updated . Source: Building Energy Benchmarking disclosure, record dc:PM19977738:2024.