The Whitman
Multifamily Housing in Washington, DC, DC · 910 M St. NW
Clean and Affordable Energy Act / BEPS · reporting year 2017
Benchmarking record
| Field | Value |
|---|---|
| ENERGY STAR score | 63 (band C) |
| Site EUI | 48.8 kBtu/ft² |
| Source EUI | 104.1 kBtu/ft² |
| GHG emissions | 719 tCO₂e |
| GHG intensity | 4.1 kgCO₂e/ft² |
| Electricity | 1,313,690 kWh |
| Natural gas | 41,820 therms |
| Water use | 6,213 kgal |
| Gross floor area | 177,379 sq ft |
| Source record | dc:PM3491858:2017 |
The disclosure history
Year over year
| Year | Score | Δ | Site EUI | GHG emissions |
|---|---|---|---|---|
| 2017latest | 63 | +1 | 48.8 kBtu/ft² | 719 tCO₂e |
| 2016 | 62 | +5 | 49.5 kBtu/ft² | 770 tCO₂e |
| 2015 | 57 | +12 | 52.7 kBtu/ft² | 899 tCO₂e |
| 2014 | 45 | 57.7 kBtu/ft² | 967 tCO₂e | |
| 2013 | — | 67.4 kBtu/ft² | 1,030 tCO₂e | |
| 2012 | — | 52.1 kBtu/ft² | 918 tCO₂e |
Compliance context
Clean and Affordable Energy Act / BEPS
DC's Building Energy Performance Standards (BEPS) require buildings below the performance standard to improve on 5-year compliance cycles, with penalties for buildings that fail to meet their pathway.
Ownership
THE WHITMAN
Own or manage this building? Claim it to correct the record and get compliance alerts.
Location
- Address
- 910 M St. NW
- City
- Washington, DC
- State
- District of Columbia
- Coordinates
- 38.90538, -77.02457
Within ~1 km
Nearby benchmarked buildings
Convention Center · 1,750,000 sq ft
Hotel · 1,081,202 sq ft
Multifamily Housing · 1,075,449 sq ft
- Capital One Arenascore —
Indoor Arena · 856,840 sq ft
- Hyatt Grand Washington DCscore 67
Hotel · 819,138 sq ft
- 1300 Buildingscore 95
Bank/Financial Institution · 803,167 sq ft
See also: most efficient in Washington, DC · biggest emitters
Frequently asked questions
What is The Whitman's energy grade?
The Whitman scores 63 out of 100 on ENERGY STAR — band C (Below median (55–69)) — in its 2017 Washington, DC disclosure. Scores are national percentiles against similar buildings; 75+ qualifies for ENERGY STAR certification.
How much energy does The Whitman use?
Its 2017 site energy-use intensity was 48.8 kBtu/ft² (104.1 kBtu/ft² source) across 177,379 sq ft, including 1,313,690 kWh of electricity and 41,820 therms of natural gas.
What are The Whitman's carbon emissions?
The Whitman reported 719 tCO₂e of greenhouse-gas emissions (4.1 kgCO₂e/ft²) for 2017. DC's Building Energy Performance Standards (BEPS) require buildings below the performance standard to improve on 5-year compliance cycles, with penalties for buildings that fail to meet their pathway.
Dataset updated . Source: Building Energy Benchmarking disclosure, record dc:PM3491858:2017.