BuildingCensus
A

120-Sepulveda

Multifamily Housing in California, CA · 7343 Sepulveda Blvd, Van Nuys · 91405

At a glance

120-Sepulveda is a 75,000-square-foot multifamily housing building at 7343 Sepulveda Blvd, Van Nuys in Van Nuys, California, built in 1963. In its 2021 California benchmarking disclosure it reported an ENERGY STAR score of 100 out of 100 (grade A), a site energy-use intensity of 29.0 kBtu/ft² and 112 tCO₂e of greenhouse-gas emissions. That score is higher than 76% of the 9,612 scored multifamily housing buildings in California.

ENERGY STAR score
100
band A · 2021
Site EUI
29.0
kBtu/ft²
GHG emissions
112
tCO₂e
GHG intensity
1.5
kgCO₂e/ft²
Floor area
75,000
sq ft
Year built
1963
vintage
◆ Loading map…
85–10070–8455–691–54
This entry + 6 nearby

AB 802 (Public Resources Code §25402.10) · reporting year 2021

Benchmarking record

FieldValue
ENERGY STAR score100 (band A)
Site EUI29.0 kBtu/ft²
Source EUI—
GHG emissions112 tCO₂e
GHG intensity1.5 kgCO₂e/ft²
Electricity25,055 kWh
Natural gas20,138 therms
Gross floor area75,000 sq ft
Source recordcalifornia:6722919:2021

The disclosure history

Year over year

YearScoreΔSite EUIGHG emissions
2021latest100±029.0 kBtu/ft²112 tCO₂e
2020100±028.9 kBtu/ft²110 tCO₂e
201910028.3 kBtu/ft²113 tCO₂e

Compliance context

AB 802 (Public Resources Code §25402.10)

AB 802 requires every California commercial building over 50,000 sq ft to report energy use to the CEC annually; the CEC publicly discloses the results statewide.

Program details →

Ownership

No owning organisation shown. Names of private individuals in the disclosure are not published here.

Own or manage this building? Claim it to correct the record and get compliance alerts.

Location

Address
7343 Sepulveda Blvd, Van Nuys
State
California
ZIP
91405
Coordinates
34.20412, -118.46620

Within ~1 km

Nearby benchmarked buildings

See also: most efficient in California · biggest emitters

How does 120-Sepulveda compare with other multifamily housing buildings in California?

The latest disclosures cover 10,630 multifamily housing buildings in California, out of 40,029 buildings citywide. 120-Sepulveda's ENERGY STAR score of 100 compares with an average of 82 across the 9,612 that report a score; it scores higher than 76% of them. Its site EUI of 29.0 kBtu/ft² is about 16% below the average of 34.4 kBtu/ft² — it uses less energy per square foot than the typical building in that group. Its emissions intensity of 1.5 kgCO₂e/ft² is about 29% below the group average of 2.1 kgCO₂e/ft².

At 75,000 sq ft, it is about half of the average floor area of 150,919 sq ft for those buildings. It was built in 1963, 25 years earlier than the group's average year built (1988). Across all 24 jurisdictions BuildingCensus covers, the 59,945 multifamily housing buildings average an ENERGY STAR score of 70 and a site EUI of 59.0 kBtu/ft².

How has 120-Sepulveda's energy performance changed over time?

BuildingCensus holds 3 California disclosures for 120-Sepulveda, covering report years 2019–2021. Its ENERGY STAR score was 100 in both 2019 and 2021. Site EUI moved from 28.3 kBtu/ft² (2019) to 29.0 kBtu/ft² (2021), an 2% increase. Reported emissions went from 113 tCO₂e to 112 tCO₂e over the same span (down 1%).

What does an ENERGY STAR score of 100 mean?

ENERGY STAR scores run from 1 to 100 and are computed by the EPA's Portfolio Manager as a percentile against similar buildings nationwide, adjusted for climate, size and use: 100 is the top of the scale. BuildingCensus bands the score into report-card grades; 100 falls in band A — high performer (85–100). Scores of 75 or higher meet the threshold for ENERGY STAR certification; certification itself is a separate, verified application that the disclosure does not record. In California, 65% of scored buildings are at 75 or above.

Site energy-use intensity (EUI) is the energy a building uses on site in a year divided by its floor area, in thousand Btu per square foot — lower is more efficient. 120-Sepulveda's 29.0 kBtu/ft² across 75,000 sq ft works out to about 2.2 billion Btu (637 MWh-equivalent) in 2021. The disclosure also reports 25,055 kWh of electricity and 20,138 therms of natural gas for the year.

Which law requires 120-Sepulveda to report its energy use?

120-Sepulveda reports under AB 802 (Public Resources Code §25402.10), the legal basis of California's Building Energy Benchmarking Program (statewide), which publishes each covered building's annual benchmarking results. The record shown here is the report-year 2021 disclosure (source record california:6722919:2021). AB 802 requires every California commercial building over 50,000 sq ft to report energy use to the CEC annually; the CEC publicly discloses the results statewide.

More multifamily housing buildings in California

Frequently asked questions

What is 120-Sepulveda's energy grade?

120-Sepulveda scores 100 out of 100 on ENERGY STAR — band A, high performer (85–100) — in its 2021 California disclosure. Scores are national percentiles against similar buildings; 75+ qualifies for ENERGY STAR certification.

How much energy does 120-Sepulveda use?

Its 2021 site energy-use intensity was 29.0 kBtu/ft² across 75,000 sq ft, including 25,055 kWh of electricity and 20,138 therms of natural gas.

What are 120-Sepulveda's carbon emissions?

120-Sepulveda reported 112 tCO₂e of greenhouse-gas emissions (1.5 kgCO₂e/ft²) for 2021.

Where is 120-Sepulveda?

120-Sepulveda is at 7343 Sepulveda Blvd, Van Nuys, in Van Nuys, California 91405. Its coordinates are 34.20412, -118.46620 (latitude, longitude), as published in the Building Energy Benchmarking Program (statewide) file.

How big is 120-Sepulveda and when was it built?

120-Sepulveda has 75,000 sq ft of gross floor area, as reported in its 2021 disclosure. The disclosure lists 1963 as its year built. It is classed as multifamily housing.

Is 120-Sepulveda covered by AB 802 (Public Resources Code §25402.10)?

Yes — it appears in the 2021 Building Energy Benchmarking Program (statewide) disclosure, which lists the buildings reporting under AB 802 (Public Resources Code §25402.10).

Working with California building benchmarking records? Pro adds alerts, change history and CSV export ($49/mo); Enterprise adds full national files, the API and an MCP server for AI tools.

About this data

Source: Building Energy Benchmarking Program (statewide) (AB 802 (Public Resources Code §25402.10)), as published July 9, 2026. See the methodology for how records are matched, cleaned and scored.

Cite as: BuildingCensus, “120-Sepulveda, Van Nuys, California — 2021 benchmarking disclosure”, https://buildingcensus.com/buildings/california/120-sepulveda-2e443c61 (data as of July 9, 2026).