2550 Great America Way
Office in California, CA · 2550 Great America Way, Santa Clara · 95054
At a glance
2550 Great America Way is a 165,780-square-foot office building at 2550 Great America Way, Santa Clara in Santa Clara, California, built in 2013. In its 2024 California benchmarking disclosure it reported an ENERGY STAR score of 58 out of 100 (grade C), a site energy-use intensity of 67.3 kBtu/ft² and 706 tCO₂e of greenhouse-gas emissions. That score is higher than 20% of the 4,912 scored office buildings in California.
AB 802 (Public Resources Code §25402.10) · reporting year 2024
Benchmarking record
| Field | Value |
|---|---|
| ENERGY STAR score | 58 (band C) |
| Site EUI | 67.3 kBtu/ft² |
| Source EUI | — |
| GHG emissions | 706 tCO₂e |
| GHG intensity | 4.3 kgCO₂e/ft² |
| Electricity | 2,220,524 kWh |
| Natural gas | 38,225 therms |
| Gross floor area | 165,780 sq ft |
| Source record | california:5734563:2024 |
The disclosure history
Year over year
| Year | Score | Δ | Site EUI | GHG emissions |
|---|---|---|---|---|
| 2024latest | 58 | ±0 | 67.3 kBtu/ft² | 706 tCO₂e |
| 2023 | 58 | -4 | 79.0 kBtu/ft² | 815 tCO₂e |
| 2022 | 62 | -14 | 73.1 kBtu/ft² | 738 tCO₂e |
| 2021 | 76 | +5 | 56.5 kBtu/ft² | 540 tCO₂e |
| 2020 | 71 | +6 | 63.7 kBtu/ft² | 634 tCO₂e |
| 2019 | 65 | -8 | 85.9 kBtu/ft² | 876 tCO₂e |
| 2018 | 73 | 64.0 kBtu/ft² | 654 tCO₂e |
Compliance context
AB 802 (Public Resources Code §25402.10)
AB 802 requires every California commercial building over 50,000 sq ft to report energy use to the CEC annually; the CEC publicly discloses the results statewide.
Ownership
No owning organisation shown. Names of private individuals in the disclosure are not published here.
Own or manage this building? Claim it to correct the record and get compliance alerts.
Location
- Address
- 2550 Great America Way, Santa Clara
- City
- California
- State
- California
- ZIP
- 95054
- Coordinates
- 37.41476, -121.97365
Within ~1 km
Nearby benchmarked buildings
- Stadium Techcenterscore —
Office · 305,632 sq ft
- Gold Streetscore —
Office · 302,649 sq ft
Office · 229,240 sq ft
- Stadium Tech - Phase Iscore —
Laboratory · 227,619 sq ft
- Ga Parkwayscore —
Office · 224,526 sq ft
- America Center Iv - 6220score 91
Office · 220,761 sq ft
See also: most efficient in California · biggest emitters
How does 2550 Great America Way compare with other office buildings in California?
The latest disclosures cover 6,214 office buildings in California, out of 40,029 buildings citywide. 2550 Great America Way's ENERGY STAR score of 58 compares with an average of 75 across the 4,912 that report a score; it scores higher than 20% of them and lower than 79%. Its site EUI of 67.3 kBtu/ft² is about 19% above the average of 56.4 kBtu/ft² — it uses more energy per square foot than the typical building in that group. Its emissions intensity of 4.3 kgCO₂e/ft² is about 18% above the group average of 3.6 kgCO₂e/ft².
At 165,780 sq ft, it is roughly in line with the average floor area of 151,937 sq ft for those buildings. It was built in 2013, 28 years later than the group's average year built (1985). Across all 24 jurisdictions BuildingCensus covers, the 15,264 office buildings average an ENERGY STAR score of 73 and a site EUI of 59.3 kBtu/ft².
How has 2550 Great America Way's energy performance changed over time?
BuildingCensus holds 7 California disclosures for 2550 Great America Way, covering report years 2018–2024. Its ENERGY STAR score went from 73 in 2018 to 58 in 2024 (-15 points); its best year on file was 2021, at 76. Site EUI moved from 64.0 kBtu/ft² (2018) to 67.3 kBtu/ft² (2024), an 5% increase. Reported emissions went from 654 tCO₂e to 706 tCO₂e over the same span (up 8%).
What does an ENERGY STAR score of 58 mean?
ENERGY STAR scores run from 1 to 100 and are computed by the EPA's Portfolio Manager as a percentile against similar buildings nationwide, adjusted for climate, size and use: a score of 58 means the building performs better than about 58% of its national peers. BuildingCensus bands the score into report-card grades; 58 falls in band C — below median (55–69). It sits 17 points below 75, the threshold for ENERGY STAR certification. In California, 65% of scored buildings are at 75 or above.
Site energy-use intensity (EUI) is the energy a building uses on site in a year divided by its floor area, in thousand Btu per square foot — lower is more efficient. 2550 Great America Way's 67.3 kBtu/ft² across 165,780 sq ft works out to about 11.2 billion Btu (3,270 MWh-equivalent) in 2024. The disclosure also reports 2,220,524 kWh of electricity and 38,225 therms of natural gas for the year.
Which law requires 2550 Great America Way to report its energy use?
2550 Great America Way reports under AB 802 (Public Resources Code §25402.10), the legal basis of California's Building Energy Benchmarking Program (statewide), which publishes each covered building's annual benchmarking results. The record shown here is the report-year 2024 disclosure (source record california:5734563:2024). AB 802 requires every California commercial building over 50,000 sq ft to report energy use to the CEC annually; the CEC publicly discloses the results statewide.
More office buildings in California
- Triangle Building· 165,630 sq ft · score 98 (A)
- Crossroads I· 165,501 sq ft · EUI 33.2 kBtu/ft²
- 1411 W 190Th St· 165,325 sq ft · score 47 (D)
- 4929 Wilshire, Lp· 165,130 sq ft · score 53 (D)
- Ca - Lottery Headquarters (Hq)· 165,077 sq ft · score 85 (A)
- Port Of San Diego Administration Bldg· 165,000 sq ft · score 71 (B)
- Office buildings in California· 6,214 benchmarked
- All California benchmarked buildings· AB 802 (Public Resources Code §25402.10)
- Most efficient large buildings in California
- Least efficient large buildings in California
- Biggest emitters in California
Frequently asked questions
What is 2550 Great America Way's energy grade?
2550 Great America Way scores 58 out of 100 on ENERGY STAR — band C, below median (55–69) — in its 2024 California disclosure. Scores are national percentiles against similar buildings; 75+ qualifies for ENERGY STAR certification.
How much energy does 2550 Great America Way use?
Its 2024 site energy-use intensity was 67.3 kBtu/ft² across 165,780 sq ft, including 2,220,524 kWh of electricity and 38,225 therms of natural gas.
What are 2550 Great America Way's carbon emissions?
2550 Great America Way reported 706 tCO₂e of greenhouse-gas emissions (4.3 kgCO₂e/ft²) for 2024.
Where is 2550 Great America Way?
2550 Great America Way is at 2550 Great America Way, Santa Clara, in Santa Clara, California 95054. Its coordinates are 37.41476, -121.97365 (latitude, longitude), as published in the Building Energy Benchmarking Program (statewide) file.
How big is 2550 Great America Way and when was it built?
2550 Great America Way has 165,780 sq ft of gross floor area, as reported in its 2024 disclosure. The disclosure lists 2013 as its year built. It is classed as office.
Is 2550 Great America Way covered by AB 802 (Public Resources Code §25402.10)?
Yes — it appears in the 2024 Building Energy Benchmarking Program (statewide) disclosure, which lists the buildings reporting under AB 802 (Public Resources Code §25402.10).
Working with California building benchmarking records? Pro adds alerts, change history and CSV export ($49/mo); Enterprise adds full national files, the API and an MCP server for AI tools.
About this data
Source: Building Energy Benchmarking Program (statewide) (AB 802 (Public Resources Code §25402.10)), as published July 9, 2026. See the methodology for how records are matched, cleaned and scored.
Cite as: BuildingCensus, “2550 Great America Way, Santa Clara, California — 2024 benchmarking disclosure”, https://buildingcensus.com/buildings/california/2550-great-america-way-dc6f71ed (data as of July 9, 2026).