390 N Pch
Office in California, CA · 390 North Pacific Coast Highway, El Segundo · 90245
At a glance
390 N Pch is a 111,546-square-foot office building at 390 North Pacific Coast Highway, El Segundo in El Segundo, California, built in 1980. In its 2020 California benchmarking disclosure it reported an ENERGY STAR score of 63 out of 100 (grade C), a site energy-use intensity of 62.7 kBtu/ft² and 424 tCO₂e of greenhouse-gas emissions. That score is higher than 24% of the 4,912 scored office buildings in California.
AB 802 (Public Resources Code §25402.10) · reporting year 2020
Benchmarking record
| Field | Value |
|---|---|
| ENERGY STAR score | 63 (band C) |
| Site EUI | 62.7 kBtu/ft² |
| Source EUI | — |
| GHG emissions | 424 tCO₂e |
| GHG intensity | 3.8 kgCO₂e/ft² |
| Electricity | 1,165,145 kWh |
| Natural gas | 30,175 therms |
| Gross floor area | 111,546 sq ft |
| Source record | california:6876970:2020 |
The disclosure history
Year over year
| Year | Score | Δ | Site EUI | GHG emissions |
|---|---|---|---|---|
| 2020latest | 63 | +15 | 62.7 kBtu/ft² | 424 tCO₂e |
| 2019 | 48 | +20 | 78.4 kBtu/ft² | 527 tCO₂e |
| 2018 | 28 | 103.3 kBtu/ft² | 733 tCO₂e |
Compliance context
AB 802 (Public Resources Code §25402.10)
AB 802 requires every California commercial building over 50,000 sq ft to report energy use to the CEC annually; the CEC publicly discloses the results statewide.
Ownership
No owning organisation shown. Names of private individuals in the disclosure are not published here.
Own or manage this building? Claim it to correct the record and get compliance alerts.
Location
- Address
- 390 North Pacific Coast Highway, El Segundo
- City
- California
- State
- California
- ZIP
- 90245
- Coordinates
- 33.92109, -118.39455
Within ~1 km
Nearby benchmarked buildings
Office · 1,054,988 sq ft
Office · 702,746 sq ft
Office · 615,565 sq ft
Office · 362,343 sq ft
- 101 Continentalscore 87
Office · 339,581 sq ft
Office · 293,163 sq ft
See also: most efficient in California · biggest emitters
How does 390 N Pch compare with other office buildings in California?
The latest disclosures cover 6,214 office buildings in California, out of 40,029 buildings citywide. 390 N Pch's ENERGY STAR score of 63 compares with an average of 75 across the 4,912 that report a score; it scores higher than 24% of them and lower than 75%. Its site EUI of 62.7 kBtu/ft² is about 11% above the average of 56.4 kBtu/ft² — it uses more energy per square foot than the typical building in that group. Its emissions intensity of 3.8 kgCO₂e/ft² is roughly in line with the group average of 3.6 kgCO₂e/ft².
At 111,546 sq ft, it is about 27% below the average floor area of 151,937 sq ft for those buildings. It was built in 1980, 5 years earlier than the group's average year built (1985). Across all 24 jurisdictions BuildingCensus covers, the 15,264 office buildings average an ENERGY STAR score of 73 and a site EUI of 59.3 kBtu/ft².
How has 390 N Pch's energy performance changed over time?
BuildingCensus holds 3 California disclosures for 390 N Pch, covering report years 2018–2020. Its ENERGY STAR score went from 28 in 2018 to 63 in 2020 (+35 points). Site EUI moved from 103.3 kBtu/ft² (2018) to 62.7 kBtu/ft² (2020), a 39% decrease. Reported emissions went from 733 tCO₂e to 424 tCO₂e over the same span (down 42%).
What does an ENERGY STAR score of 63 mean?
ENERGY STAR scores run from 1 to 100 and are computed by the EPA's Portfolio Manager as a percentile against similar buildings nationwide, adjusted for climate, size and use: a score of 63 means the building performs better than about 63% of its national peers. BuildingCensus bands the score into report-card grades; 63 falls in band C — below median (55–69). It sits 12 points below 75, the threshold for ENERGY STAR certification. In California, 65% of scored buildings are at 75 or above.
Site energy-use intensity (EUI) is the energy a building uses on site in a year divided by its floor area, in thousand Btu per square foot — lower is more efficient. 390 N Pch's 62.7 kBtu/ft² across 111,546 sq ft works out to about 7 billion Btu (2,050 MWh-equivalent) in 2020. The disclosure also reports 1,165,145 kWh of electricity and 30,175 therms of natural gas for the year.
Which law requires 390 N Pch to report its energy use?
390 N Pch reports under AB 802 (Public Resources Code §25402.10), the legal basis of California's Building Energy Benchmarking Program (statewide), which publishes each covered building's annual benchmarking results. The record shown here is the report-year 2020 disclosure (source record california:6876970:2020). AB 802 requires every California commercial building over 50,000 sq ft to report energy use to the CEC annually; the CEC publicly discloses the results statewide.
More office buildings in California
- 390 N Sepulveda Blvd.· 111,516 sq ft · score 54 (D)
- Menlo Business Park· 111,512 sq ft · EUI 0.2 kBtu/ft²
- 6101 Centinela· 111,473 sq ft · score 62 (C)
- Fre 125· 111,465 sq ft · score 29 (D)
- Swift Cerritos 12911· 111,444 sq ft · score 62 (C)
- 09946- Pleasanton, Ca· 111,421 sq ft · score 28 (D)
- Office buildings in California· 6,214 benchmarked
- All California benchmarked buildings· AB 802 (Public Resources Code §25402.10)
- Most efficient large buildings in California
- Least efficient large buildings in California
- Biggest emitters in California
Frequently asked questions
What is 390 N Pch's energy grade?
390 N Pch scores 63 out of 100 on ENERGY STAR — band C, below median (55–69) — in its 2020 California disclosure. Scores are national percentiles against similar buildings; 75+ qualifies for ENERGY STAR certification.
How much energy does 390 N Pch use?
Its 2020 site energy-use intensity was 62.7 kBtu/ft² across 111,546 sq ft, including 1,165,145 kWh of electricity and 30,175 therms of natural gas.
What are 390 N Pch's carbon emissions?
390 N Pch reported 424 tCO₂e of greenhouse-gas emissions (3.8 kgCO₂e/ft²) for 2020.
Where is 390 N Pch?
390 N Pch is at 390 North Pacific Coast Highway, El Segundo, in El Segundo, California 90245. Its coordinates are 33.92109, -118.39455 (latitude, longitude), as published in the Building Energy Benchmarking Program (statewide) file.
How big is 390 N Pch and when was it built?
390 N Pch has 111,546 sq ft of gross floor area, as reported in its 2020 disclosure. The disclosure lists 1980 as its year built. It is classed as office.
Is 390 N Pch covered by AB 802 (Public Resources Code §25402.10)?
Yes — it appears in the 2020 Building Energy Benchmarking Program (statewide) disclosure, which lists the buildings reporting under AB 802 (Public Resources Code §25402.10).
Working with California building benchmarking records? Pro adds alerts, change history and CSV export ($49/mo); Enterprise adds full national files, the API and an MCP server for AI tools.
About this data
Source: Building Energy Benchmarking Program (statewide) (AB 802 (Public Resources Code §25402.10)), as published July 9, 2026. See the methodology for how records are matched, cleaned and scored.
Cite as: BuildingCensus, “390 N Pch, El Segundo, California — 2020 benchmarking disclosure”, https://buildingcensus.com/buildings/california/390-n-pch-d92c8500 (data as of July 9, 2026).