BuildingCensus
A

Holiday Inn Dublin

Hotel in California, CA · 6680 Regional Street, Dublin · 94568

At a glance

Holiday Inn Dublin is a 121,069-square-foot hotel at 6680 Regional Street, Dublin in Dublin, California, built in 1997. In its 2024 California benchmarking disclosure it reported an ENERGY STAR score of 98 out of 100 (grade A), a site energy-use intensity of 21.4 kBtu/ft² and 168 tCO₂e of greenhouse-gas emissions. That score is higher than 85% of the 1,525 scored hotel buildings in California.

ENERGY STAR score
98
band A · 2024
Site EUI
21.4
kBtu/ft²
GHG emissions
168
tCO₂e
GHG intensity
1.4
kgCO₂e/ft²
Floor area
121,069
sq ft
Year built
1997
vintage
◆ Loading map…
85–10070–8455–691–54
This entry + 6 nearby

AB 802 (Public Resources Code §25402.10) · reporting year 2024

Benchmarking record

FieldValue
ENERGY STAR score98 (band A)
Site EUI21.4 kBtu/ft²
Source EUI—
GHG emissions168 tCO₂e
GHG intensity1.4 kgCO₂e/ft²
Electricity743,480 kWh
Gross floor area121,069 sq ft
Source recordcalifornia:36491863:2024

The disclosure history

Year over year

YearScoreΔSite EUIGHG emissions
2024latest98±021.4 kBtu/ft²168 tCO₂e
20239821.9 kBtu/ft²176 tCO₂e

Compliance context

AB 802 (Public Resources Code §25402.10)

AB 802 requires every California commercial building over 50,000 sq ft to report energy use to the CEC annually; the CEC publicly discloses the results statewide.

Program details →

Ownership

No owning organisation shown. Names of private individuals in the disclosure are not published here.

Own or manage this building? Claim it to correct the record and get compliance alerts.

Location

Address
6680 Regional Street, Dublin
State
California
ZIP
94568
Coordinates
37.70008, -121.93322

Within ~1 km

Nearby benchmarked buildings

See also: most efficient in California · biggest emitters

How does Holiday Inn Dublin compare with other hotel buildings in California?

The latest disclosures cover 1,599 hotel buildings in California, out of 40,029 buildings citywide. Holiday Inn Dublin's ENERGY STAR score of 98 compares with an average of 74 across the 1,525 that report a score; it scores higher than 85% of them and lower than 12%. Its site EUI of 21.4 kBtu/ft² is about 67% below the average of 65.6 kBtu/ft² — it uses less energy per square foot than the typical building in that group. Its emissions intensity of 1.4 kgCO₂e/ft² is about 65% below the group average of 4.0 kgCO₂e/ft².

At 121,069 sq ft, it is about 28% below the average floor area of 167,786 sq ft for those buildings. It was built in 1997, 9 years later than the group's average year built (1988). Across all 24 jurisdictions BuildingCensus covers, the 3,812 hotel buildings average an ENERGY STAR score of 65 and a site EUI of 77.8 kBtu/ft².

How has Holiday Inn Dublin's energy performance changed over time?

BuildingCensus holds 2 California disclosures for Holiday Inn Dublin, covering report years 2023–2024. Its ENERGY STAR score was 98 in both 2023 and 2024. Site EUI moved from 21.9 kBtu/ft² (2023) to 21.4 kBtu/ft² (2024), a 2% decrease. Reported emissions went from 176 tCO₂e to 168 tCO₂e over the same span (down 4%).

What does an ENERGY STAR score of 98 mean?

ENERGY STAR scores run from 1 to 100 and are computed by the EPA's Portfolio Manager as a percentile against similar buildings nationwide, adjusted for climate, size and use: a score of 98 means the building performs better than about 98% of its national peers. BuildingCensus bands the score into report-card grades; 98 falls in band A — high performer (85–100). Scores of 75 or higher meet the threshold for ENERGY STAR certification; certification itself is a separate, verified application that the disclosure does not record. In California, 65% of scored buildings are at 75 or above.

Site energy-use intensity (EUI) is the energy a building uses on site in a year divided by its floor area, in thousand Btu per square foot — lower is more efficient. Holiday Inn Dublin's 21.4 kBtu/ft² across 121,069 sq ft works out to about 2.6 billion Btu (759 MWh-equivalent) in 2024. The disclosure also reports 743,480 kWh of electricity for the year.

Which law requires Holiday Inn Dublin to report its energy use?

Holiday Inn Dublin reports under AB 802 (Public Resources Code §25402.10), the legal basis of California's Building Energy Benchmarking Program (statewide), which publishes each covered building's annual benchmarking results. The record shown here is the report-year 2024 disclosure (source record california:36491863:2024). AB 802 requires every California commercial building over 50,000 sq ft to report energy use to the CEC annually; the CEC publicly discloses the results statewide.

More hotel buildings in California

Frequently asked questions

What is Holiday Inn Dublin's energy grade?

Holiday Inn Dublin scores 98 out of 100 on ENERGY STAR — band A, high performer (85–100) — in its 2024 California disclosure. Scores are national percentiles against similar buildings; 75+ qualifies for ENERGY STAR certification.

How much energy does Holiday Inn Dublin use?

Its 2024 site energy-use intensity was 21.4 kBtu/ft² across 121,069 sq ft, including 743,480 kWh of electricity.

What are Holiday Inn Dublin's carbon emissions?

Holiday Inn Dublin reported 168 tCO₂e of greenhouse-gas emissions (1.4 kgCO₂e/ft²) for 2024.

Where is Holiday Inn Dublin?

Holiday Inn Dublin is at 6680 Regional Street, Dublin, in Dublin, California 94568. Its coordinates are 37.70008, -121.93322 (latitude, longitude), as published in the Building Energy Benchmarking Program (statewide) file.

How big is Holiday Inn Dublin and when was it built?

Holiday Inn Dublin has 121,069 sq ft of gross floor area, as reported in its 2024 disclosure. The disclosure lists 1997 as its year built. It is classed as hotel.

Is Holiday Inn Dublin covered by AB 802 (Public Resources Code §25402.10)?

Yes — it appears in the 2024 Building Energy Benchmarking Program (statewide) disclosure, which lists the buildings reporting under AB 802 (Public Resources Code §25402.10).

Working with California building benchmarking records? Pro adds alerts, change history and CSV export ($49/mo); Enterprise adds full national files, the API and an MCP server for AI tools.

About this data

Source: Building Energy Benchmarking Program (statewide) (AB 802 (Public Resources Code §25402.10)), as published July 9, 2026. See the methodology for how records are matched, cleaned and scored.

Cite as: BuildingCensus, “Holiday Inn Dublin, Dublin, California — 2024 benchmarking disclosure”, https://buildingcensus.com/buildings/california/holiday-inn-dublin-f4a4bb1a (data as of July 9, 2026).