BuildingCensus
A

Kingsview Industrial

Non-Refrigerated Warehouse in California, CA · 17120 Kingsview Avenue, Carson · 90746

At a glance

Kingsview Industrial is a 82,920-square-foot non-refrigerated warehouse at 17120 Kingsview Avenue, Carson in Carson, California, built in 1979. In its 2024 California benchmarking disclosure it reported an ENERGY STAR score of 100 out of 100 (grade A), a site energy-use intensity of 3.1 kBtu/ft² and 17 tCO₂e of greenhouse-gas emissions. That score is higher than 92% of the 2,227 scored non-refrigerated warehouse buildings in California.

ENERGY STAR score
100
band A · 2024
Site EUI
3.1
kBtu/ft²
GHG emissions
17
tCO₂e
GHG intensity
0.2
kgCO₂e/ft²
Floor area
82,920
sq ft
Year built
1979
vintage
◆ Loading map…
85–10070–8455–691–54
This entry + 6 nearby

AB 802 (Public Resources Code §25402.10) · reporting year 2024

Benchmarking record

FieldValue
ENERGY STAR score100 (band A)
Site EUI3.1 kBtu/ft²
Source EUI—
GHG emissions17 tCO₂e
GHG intensity0.2 kgCO₂e/ft²
Electricity76,318 kWh
Gross floor area82,920 sq ft
Source recordcalifornia:6393437:2024

The disclosure history

Year over year

YearScoreΔSite EUIGHG emissions
2024latest100+83.1 kBtu/ft²17 tCO₂e
202392+185.6 kBtu/ft²33 tCO₂e
2022745.7 kBtu/ft²32 tCO₂e

Compliance context

AB 802 (Public Resources Code §25402.10)

AB 802 requires every California commercial building over 50,000 sq ft to report energy use to the CEC annually; the CEC publicly discloses the results statewide.

Program details →

Ownership

No owning organisation shown. Names of private individuals in the disclosure are not published here.

Own or manage this building? Claim it to correct the record and get compliance alerts.

Location

Address
17120 Kingsview Avenue, Carson
State
California
ZIP
90746
Coordinates
33.87658, -118.26125

Within ~1 km

Nearby benchmarked buildings

See also: most efficient in California · biggest emitters

How does Kingsview Industrial compare with other non-refrigerated warehouse buildings in California?

The latest disclosures cover 2,867 non-refrigerated warehouse buildings in California, out of 40,029 buildings citywide. Kingsview Industrial's ENERGY STAR score of 100 compares with an average of 68 across the 2,227 that report a score; it scores higher than 92% of them. Its site EUI of 3.1 kBtu/ft² is about 86% below the average of 21.7 kBtu/ft² — it uses less energy per square foot than the typical building in that group. Its emissions intensity of 0.2 kgCO₂e/ft² is about 85% below the group average of 1.4 kgCO₂e/ft².

At 82,920 sq ft, it is about half of the average floor area of 173,929 sq ft for those buildings. It was built in 1979, 9 years earlier than the group's average year built (1988). Across all 24 jurisdictions BuildingCensus covers, the 4,723 non-refrigerated warehouse buildings average an ENERGY STAR score of 66 and a site EUI of 26.0 kBtu/ft².

How has Kingsview Industrial's energy performance changed over time?

BuildingCensus holds 3 California disclosures for Kingsview Industrial, covering report years 2022–2024. Its ENERGY STAR score went from 74 in 2022 to 100 in 2024 (+26 points). Site EUI moved from 5.7 kBtu/ft² (2022) to 3.1 kBtu/ft² (2024), a 46% decrease. Reported emissions went from 32 tCO₂e to 17 tCO₂e over the same span (down 46%).

What does an ENERGY STAR score of 100 mean?

ENERGY STAR scores run from 1 to 100 and are computed by the EPA's Portfolio Manager as a percentile against similar buildings nationwide, adjusted for climate, size and use: 100 is the top of the scale. BuildingCensus bands the score into report-card grades; 100 falls in band A — high performer (85–100). Scores of 75 or higher meet the threshold for ENERGY STAR certification; certification itself is a separate, verified application that the disclosure does not record. In California, 65% of scored buildings are at 75 or above.

Site energy-use intensity (EUI) is the energy a building uses on site in a year divided by its floor area, in thousand Btu per square foot — lower is more efficient. Kingsview Industrial's 3.1 kBtu/ft² across 82,920 sq ft works out to about 0.3 billion Btu (75 MWh-equivalent) in 2024. The disclosure also reports 76,318 kWh of electricity for the year.

Which law requires Kingsview Industrial to report its energy use?

Kingsview Industrial reports under AB 802 (Public Resources Code §25402.10), the legal basis of California's Building Energy Benchmarking Program (statewide), which publishes each covered building's annual benchmarking results. The record shown here is the report-year 2024 disclosure (source record california:6393437:2024). AB 802 requires every California commercial building over 50,000 sq ft to report energy use to the CEC annually; the CEC publicly discloses the results statewide.

More non-refrigerated warehouse buildings in California

Frequently asked questions

What is Kingsview Industrial's energy grade?

Kingsview Industrial scores 100 out of 100 on ENERGY STAR — band A, high performer (85–100) — in its 2024 California disclosure. Scores are national percentiles against similar buildings; 75+ qualifies for ENERGY STAR certification.

How much energy does Kingsview Industrial use?

Its 2024 site energy-use intensity was 3.1 kBtu/ft² across 82,920 sq ft, including 76,318 kWh of electricity.

What are Kingsview Industrial's carbon emissions?

Kingsview Industrial reported 17 tCO₂e of greenhouse-gas emissions (0.2 kgCO₂e/ft²) for 2024.

Where is Kingsview Industrial?

Kingsview Industrial is at 17120 Kingsview Avenue, Carson, in Carson, California 90746. Its coordinates are 33.87658, -118.26125 (latitude, longitude), as published in the Building Energy Benchmarking Program (statewide) file.

How big is Kingsview Industrial and when was it built?

Kingsview Industrial has 82,920 sq ft of gross floor area, as reported in its 2024 disclosure. The disclosure lists 1979 as its year built. It is classed as non-refrigerated warehouse.

Is Kingsview Industrial covered by AB 802 (Public Resources Code §25402.10)?

Yes — it appears in the 2024 Building Energy Benchmarking Program (statewide) disclosure, which lists the buildings reporting under AB 802 (Public Resources Code §25402.10).

Working with California building benchmarking records? Pro adds alerts, change history and CSV export ($49/mo); Enterprise adds full national files, the API and an MCP server for AI tools.

About this data

Source: Building Energy Benchmarking Program (statewide) (AB 802 (Public Resources Code §25402.10)), as published July 9, 2026. See the methodology for how records are matched, cleaned and scored.

Cite as: BuildingCensus, “Kingsview Industrial, Carson, California — 2024 benchmarking disclosure”, https://buildingcensus.com/buildings/california/kingsview-industrial-67152518 (data as of July 9, 2026).