Sap - 3475 Deer Creek - Building 08

Office in California, CA · 3475 Deer Creek Rd, Palo Alto · 94304

At a glance

Sap - 3475 Deer Creek - Building 08 is a 53,470-square-foot office building at 3475 Deer Creek Rd, Palo Alto in Palo Alto, California, built in 1977. In its 2018 California benchmarking disclosure it reported an ENERGY STAR score of 81 out of 100 (grade B), a site energy-use intensity of 78.2 kBtu/ft² and 250 tCO₂e of greenhouse-gas emissions. That score is higher than 44% of the 4,912 scored office buildings in California.

ENERGY STAR score
81
band B · 2018
Site EUI
78.2
kBtu/ft²
GHG emissions
250
tCO₂e
GHG intensity
4.7
kgCO₂e/ft²
Floor area
53,470
sq ft
Year built
1977
vintage
◆ Loading map…
85–10070–8455–691–54
This entry + 6 nearby

AB 802 (Public Resources Code §25402.10) · reporting year 2018

Benchmarking record

FieldValue
ENERGY STAR score81 (band B)
Site EUI78.2 kBtu/ft²
Source EUI—
GHG emissions250 tCO₂e
GHG intensity4.7 kgCO₂e/ft²
Electricity631,619 kWh
Natural gas20,112 therms
Gross floor area53,470 sq ft
Source recordcalifornia:4383428:2018

Compliance context

AB 802 (Public Resources Code §25402.10)

AB 802 requires every California commercial building over 50,000 sq ft to report energy use to the CEC annually; the CEC publicly discloses the results statewide.

Program details →

Ownership

No owning organisation shown. Names of private individuals in the disclosure are not published here.

Own or manage this building? Claim it to correct the record and get compliance alerts.

Location

Address
3475 Deer Creek Rd, Palo Alto
State
California
ZIP
94304
Coordinates
37.39564, -122.14828

Within ~1 km

Nearby benchmarked buildings

See also: most efficient in California · biggest emitters

How does Sap - 3475 Deer Creek - Building 08 compare with other office buildings in California?

The latest disclosures cover 6,214 office buildings in California, out of 40,029 buildings citywide. Sap - 3475 Deer Creek - Building 08's ENERGY STAR score of 81 compares with an average of 75 across the 4,912 that report a score; it scores higher than 44% of them and lower than 54%. Its site EUI of 78.2 kBtu/ft² is about 39% above the average of 56.4 kBtu/ft² — it uses more energy per square foot than the typical building in that group. Its emissions intensity of 4.7 kgCO₂e/ft² is about 30% above the group average of 3.6 kgCO₂e/ft².

At 53,470 sq ft, it is about 65% below the average floor area of 151,937 sq ft for those buildings. It was built in 1977, 8 years earlier than the group's average year built (1985). Across all 24 jurisdictions BuildingCensus covers, the 15,264 office buildings average an ENERGY STAR score of 73 and a site EUI of 59.3 kBtu/ft².

What does an ENERGY STAR score of 81 mean?

ENERGY STAR scores run from 1 to 100 and are computed by the EPA's Portfolio Manager as a percentile against similar buildings nationwide, adjusted for climate, size and use: a score of 81 means the building performs better than about 81% of its national peers. BuildingCensus bands the score into report-card grades; 81 falls in band B — above median (70–84). Scores of 75 or higher meet the threshold for ENERGY STAR certification; certification itself is a separate, verified application that the disclosure does not record. In California, 65% of scored buildings are at 75 or above.

Site energy-use intensity (EUI) is the energy a building uses on site in a year divided by its floor area, in thousand Btu per square foot — lower is more efficient. Sap - 3475 Deer Creek - Building 08's 78.2 kBtu/ft² across 53,470 sq ft works out to about 4.2 billion Btu (1,225 MWh-equivalent) in 2018. The disclosure also reports 631,619 kWh of electricity and 20,112 therms of natural gas for the year.

Which law requires Sap - 3475 Deer Creek - Building 08 to report its energy use?

Sap - 3475 Deer Creek - Building 08 reports under AB 802 (Public Resources Code §25402.10), the legal basis of California's Building Energy Benchmarking Program (statewide), which publishes each covered building's annual benchmarking results. The record shown here is the report-year 2018 disclosure (source record california:4383428:2018). AB 802 requires every California commercial building over 50,000 sq ft to report energy use to the CEC annually; the CEC publicly discloses the results statewide.

More office buildings in California

Frequently asked questions

What is Sap - 3475 Deer Creek - Building 08's energy grade?

Sap - 3475 Deer Creek - Building 08 scores 81 out of 100 on ENERGY STAR — band B, above median (70–84) — in its 2018 California disclosure. Scores are national percentiles against similar buildings; 75+ qualifies for ENERGY STAR certification.

How much energy does Sap - 3475 Deer Creek - Building 08 use?

Its 2018 site energy-use intensity was 78.2 kBtu/ft² across 53,470 sq ft, including 631,619 kWh of electricity and 20,112 therms of natural gas.

What are Sap - 3475 Deer Creek - Building 08's carbon emissions?

Sap - 3475 Deer Creek - Building 08 reported 250 tCO₂e of greenhouse-gas emissions (4.7 kgCO₂e/ft²) for 2018.

Where is Sap - 3475 Deer Creek - Building 08?

Sap - 3475 Deer Creek - Building 08 is at 3475 Deer Creek Rd, Palo Alto, in Palo Alto, California 94304. Its coordinates are 37.39564, -122.14828 (latitude, longitude), as published in the Building Energy Benchmarking Program (statewide) file.

How big is Sap - 3475 Deer Creek - Building 08 and when was it built?

Sap - 3475 Deer Creek - Building 08 has 53,470 sq ft of gross floor area, as reported in its 2018 disclosure. The disclosure lists 1977 as its year built. It is classed as office.

Is Sap - 3475 Deer Creek - Building 08 covered by AB 802 (Public Resources Code §25402.10)?

Yes — it appears in the 2018 Building Energy Benchmarking Program (statewide) disclosure, which lists the buildings reporting under AB 802 (Public Resources Code §25402.10).

Working with California building benchmarking records? Pro adds alerts, change history and CSV export ($49/mo); Enterprise adds full national files, the API and an MCP server for AI tools.

About this data

Source: Building Energy Benchmarking Program (statewide) (AB 802 (Public Resources Code §25402.10)), as published July 9, 2026. See the methodology for how records are matched, cleaned and scored.

Cite as: BuildingCensus, “Sap - 3475 Deer Creek - Building 08, Palo Alto, California — 2018 benchmarking disclosure”, https://buildingcensus.com/buildings/california/sap-3475-deer-creek-building-08-1212460f (data as of July 9, 2026).