BuildingCensus
B

Woodland Plaza Building B

Office in California, CA · 21243 Ventura Blvd., Woodland Hills · 91367

At a glance

Woodland Plaza Building B is a 50,727-square-foot office building at 21243 Ventura Blvd., Woodland Hills in Woodland Hills, California, built in 1972. In its 2019 California benchmarking disclosure it reported an ENERGY STAR score of 73 out of 100 (grade B), a site energy-use intensity of 47.3 kBtu/ft² and 143 tCO₂e of greenhouse-gas emissions. That score is higher than 33% of the 4,912 scored office buildings in California.

ENERGY STAR score
73
band B · 2019
Site EUI
47.3
kBtu/ft²
GHG emissions
143
tCO₂e
GHG intensity
2.8
kgCO₂e/ft²
Floor area
50,727
sq ft
Year built
1972
vintage
◆ Loading map…
85–10070–8455–691–54
This entry + 6 nearby

AB 802 (Public Resources Code §25402.10) · reporting year 2019

Benchmarking record

FieldValue
ENERGY STAR score73 (band B)
Site EUI47.3 kBtu/ft²
Source EUI—
GHG emissions143 tCO₂e
GHG intensity2.8 kgCO₂e/ft²
Electricity353,554 kWh
Natural gas11,826 therms
Gross floor area50,727 sq ft
Source recordcalifornia:6216151:2019

The disclosure history

Year over year

YearScoreΔSite EUIGHG emissions
2019latest73+347.3 kBtu/ft²143 tCO₂e
20187046.8 kBtu/ft²146 tCO₂e

Compliance context

AB 802 (Public Resources Code §25402.10)

AB 802 requires every California commercial building over 50,000 sq ft to report energy use to the CEC annually; the CEC publicly discloses the results statewide.

Program details →

Ownership

No owning organisation shown. Names of private individuals in the disclosure are not published here.

Own or manage this building? Claim it to correct the record and get compliance alerts.

Location

Address
21243 Ventura Blvd., Woodland Hills
State
California
ZIP
91367
Coordinates
34.16737, -118.59501

Within ~1 km

Nearby benchmarked buildings

See also: most efficient in California · biggest emitters

How does Woodland Plaza Building B compare with other office buildings in California?

The latest disclosures cover 6,214 office buildings in California, out of 40,029 buildings citywide. Woodland Plaza Building B's ENERGY STAR score of 73 compares with an average of 75 across the 4,912 that report a score; it scores higher than 33% of them and lower than 66%. Its site EUI of 47.3 kBtu/ft² is about 16% below the average of 56.4 kBtu/ft² — it uses less energy per square foot than the typical building in that group. Its emissions intensity of 2.8 kgCO₂e/ft² is about 22% below the group average of 3.6 kgCO₂e/ft².

At 50,727 sq ft, it is about 67% below the average floor area of 151,937 sq ft for those buildings. It was built in 1972, 13 years earlier than the group's average year built (1985). Across all 24 jurisdictions BuildingCensus covers, the 15,264 office buildings average an ENERGY STAR score of 73 and a site EUI of 59.3 kBtu/ft².

How has Woodland Plaza Building B's energy performance changed over time?

BuildingCensus holds 2 California disclosures for Woodland Plaza Building B, covering report years 2018–2019. Its ENERGY STAR score went from 70 in 2018 to 73 in 2019 (+3 points). Site EUI moved from 46.8 kBtu/ft² (2018) to 47.3 kBtu/ft² (2019), an 1% increase. Reported emissions went from 146 tCO₂e to 143 tCO₂e over the same span (down 2%).

What does an ENERGY STAR score of 73 mean?

ENERGY STAR scores run from 1 to 100 and are computed by the EPA's Portfolio Manager as a percentile against similar buildings nationwide, adjusted for climate, size and use: a score of 73 means the building performs better than about 73% of its national peers. BuildingCensus bands the score into report-card grades; 73 falls in band B — above median (70–84). It sits 2 points below 75, the threshold for ENERGY STAR certification. In California, 65% of scored buildings are at 75 or above.

Site energy-use intensity (EUI) is the energy a building uses on site in a year divided by its floor area, in thousand Btu per square foot — lower is more efficient. Woodland Plaza Building B's 47.3 kBtu/ft² across 50,727 sq ft works out to about 2.4 billion Btu (703 MWh-equivalent) in 2019. The disclosure also reports 353,554 kWh of electricity and 11,826 therms of natural gas for the year.

Which law requires Woodland Plaza Building B to report its energy use?

Woodland Plaza Building B reports under AB 802 (Public Resources Code §25402.10), the legal basis of California's Building Energy Benchmarking Program (statewide), which publishes each covered building's annual benchmarking results. The record shown here is the report-year 2019 disclosure (source record california:6216151:2019). AB 802 requires every California commercial building over 50,000 sq ft to report energy use to the CEC annually; the CEC publicly discloses the results statewide.

More office buildings in California

Frequently asked questions

What is Woodland Plaza Building B's energy grade?

Woodland Plaza Building B scores 73 out of 100 on ENERGY STAR — band B, above median (70–84) — in its 2019 California disclosure. Scores are national percentiles against similar buildings; 75+ qualifies for ENERGY STAR certification.

How much energy does Woodland Plaza Building B use?

Its 2019 site energy-use intensity was 47.3 kBtu/ft² across 50,727 sq ft, including 353,554 kWh of electricity and 11,826 therms of natural gas.

What are Woodland Plaza Building B's carbon emissions?

Woodland Plaza Building B reported 143 tCO₂e of greenhouse-gas emissions (2.8 kgCO₂e/ft²) for 2019.

Where is Woodland Plaza Building B?

Woodland Plaza Building B is at 21243 Ventura Blvd., Woodland Hills, in Woodland Hills, California 91367. Its coordinates are 34.16737, -118.59501 (latitude, longitude), as published in the Building Energy Benchmarking Program (statewide) file.

How big is Woodland Plaza Building B and when was it built?

Woodland Plaza Building B has 50,727 sq ft of gross floor area, as reported in its 2019 disclosure. The disclosure lists 1972 as its year built. It is classed as office.

Is Woodland Plaza Building B covered by AB 802 (Public Resources Code §25402.10)?

Yes — it appears in the 2019 Building Energy Benchmarking Program (statewide) disclosure, which lists the buildings reporting under AB 802 (Public Resources Code §25402.10).

Working with California building benchmarking records? Pro adds alerts, change history and CSV export ($49/mo); Enterprise adds full national files, the API and an MCP server for AI tools.

About this data

Source: Building Energy Benchmarking Program (statewide) (AB 802 (Public Resources Code §25402.10)), as published July 9, 2026. See the methodology for how records are matched, cleaned and scored.

Cite as: BuildingCensus, “Woodland Plaza Building B, Woodland Hills, California — 2019 benchmarking disclosure”, https://buildingcensus.com/buildings/california/woodland-plaza-building-b-660ecefb (data as of July 9, 2026).