At a glance

178 Coolidge Hill is a 21,553-square-foot K-12 school in Cambridge, Massachusetts, built in 1930. In its 2024 Cambridge benchmarking disclosure it reported an ENERGY STAR score of 29 out of 100 (grade D), a site energy-use intensity of 60.3 kBtu/ft² and 91 tCO₂e of greenhouse-gas emissions. That score is higher than 18% of the 38 scored K-12 school buildings in Cambridge.

ENERGY STAR score
29
band D · 2024
Site EUI
60.3
kBtu/ft²
GHG emissions
91
tCO₂e
GHG intensity
—
kgCO₂e/ft²
Floor area
21,553
sq ft
Year built
1930
vintage
◆ Loading map…
85–10070–8455–691–54
This entry + 6 nearby

BEUDO · reporting year 2024

Benchmarking record

FieldValue
ENERGY STAR score29 (band D)
Site EUI60.3 kBtu/ft²
Source EUI157.1 kBtu/ft²
GHG emissions91 tCO₂e
GHG intensity—
Electricity338,400 kWh
Natural gas1,461 therms
Gross floor area21,553 sq ft
Source recordcambridge:B1367:2024

The disclosure history

Year over year

YearScoreΔSite EUIGHG emissions
2024latest29-460.3 kBtu/ft²91 tCO₂e
202333+257.6 kBtu/ft²87 tCO₂e
202231-661.9 kBtu/ft²92 tCO₂e
202137+2556.9 kBtu/ft²86 tCO₂e
202012+1097.5 kBtu/ft²74 tCO₂e
20192-3135.7 kBtu/ft²96 tCO₂e
20185+2122.9 kBtu/ft²92 tCO₂e
20173+1130.3 kBtu/ft²104 tCO₂e
20162-1131.1 kBtu/ft²105 tCO₂e
20153125.0 kBtu/ft²95 tCO₂e

Compliance context

BEUDO

Cambridge's 2023 BEUDO amendments require non-residential buildings of 100,000+ sq ft to reach net-zero emissions by 2035 (reductions starting 2026) and those of 25,000–100,000 sq ft by 2050 (starting 2030).

Program details →

Ownership

SHADY HILL SCHOOL

Own or manage this building? Claim it to correct the record and get compliance alerts.

Location

Address
178 Coolidge Hill
State
Massachusetts
Coordinates
42.37120, -71.13790

Within ~1 km

Nearby benchmarked buildings

See also: most efficient in Cambridge · biggest emitters

How does 178 Coolidge Hill compare with other K-12 school buildings in Cambridge?

The latest disclosures cover 45 K-12 school buildings in Cambridge, out of 902 buildings citywide. 178 Coolidge Hill's ENERGY STAR score of 29 compares with an average of 60 across the 38 that report a score; it scores higher than 18% of them and lower than 79%. Its site EUI of 60.3 kBtu/ft² is roughly in line with the average of 62.4 kBtu/ft² — it uses less energy per square foot than the typical building in that group.

At 21,553 sq ft, it is about 65% below the average floor area of 61,739 sq ft for those buildings. It was built in 1930, 26 years earlier than the group's average year built (1956). Across all 24 jurisdictions BuildingCensus covers, the 6,548 K-12 school buildings average an ENERGY STAR score of 64 and a site EUI of 52.7 kBtu/ft².

How has 178 Coolidge Hill's energy performance changed over time?

BuildingCensus holds 10 Cambridge disclosures for 178 Coolidge Hill, covering report years 2015–2024. Its ENERGY STAR score went from 3 in 2015 to 29 in 2024 (+26 points); its best year on file was 2021, at 37. Site EUI moved from 125.0 kBtu/ft² (2015) to 60.3 kBtu/ft² (2024), a 52% decrease. Reported emissions went from 95 tCO₂e to 91 tCO₂e over the same span (down 4%).

What does an ENERGY STAR score of 29 mean?

ENERGY STAR scores run from 1 to 100 and are computed by the EPA's Portfolio Manager as a percentile against similar buildings nationwide, adjusted for climate, size and use: a score of 29 means the building performs better than about 29% of its national peers. BuildingCensus bands the score into report-card grades; 29 falls in band D — lowest band (1–54). It sits 46 points below 75, the threshold for ENERGY STAR certification. In Cambridge, 50% of scored buildings are at 75 or above.

Site energy-use intensity (EUI) is the energy a building uses on site in a year divided by its floor area, in thousand Btu per square foot — lower is more efficient. 178 Coolidge Hill's 60.3 kBtu/ft² across 21,553 sq ft works out to about 1.3 billion Btu (381 MWh-equivalent) in 2024. Its source EUI of 157.1 kBtu/ft² also counts the energy lost generating and delivering that power, which is why it is higher. The disclosure also reports 338,400 kWh of electricity and 1,461 therms of natural gas for the year.

Which law requires 178 Coolidge Hill to report its energy use?

178 Coolidge Hill reports under BEUDO, the legal basis of Cambridge's Building Energy Use Disclosure Ordinance (BEUDO), which publishes each covered building's annual benchmarking results. The record shown here is the report-year 2024 disclosure (source record cambridge:B1367:2024). Cambridge's 2023 BEUDO amendments require non-residential buildings of 100,000+ sq ft to reach net-zero emissions by 2035 (reductions starting 2026) and those of 25,000–100,000 sq ft by 2050 (starting 2030).

More K-12 school buildings in Cambridge

Frequently asked questions

What is 178 Coolidge Hill's energy grade?

178 Coolidge Hill scores 29 out of 100 on ENERGY STAR — band D, lowest band (1–54) — in its 2024 Cambridge disclosure. Scores are national percentiles against similar buildings; 75+ qualifies for ENERGY STAR certification.

How much energy does 178 Coolidge Hill use?

Its 2024 site energy-use intensity was 60.3 kBtu/ft² (157.1 kBtu/ft² source) across 21,553 sq ft, including 338,400 kWh of electricity and 1,461 therms of natural gas.

What are 178 Coolidge Hill's carbon emissions?

178 Coolidge Hill reported 91 tCO₂e of greenhouse-gas emissions for 2024.

Where is 178 Coolidge Hill?

178 Coolidge Hill is in Cambridge, Massachusetts. Its coordinates are 42.37120, -71.13790 (latitude, longitude), as published in the Building Energy Use Disclosure Ordinance (BEUDO) file.

How big is 178 Coolidge Hill and when was it built?

178 Coolidge Hill has 21,553 sq ft of gross floor area, as reported in its 2024 disclosure. The disclosure lists 1930 as its year built. It is classed as K-12 school.

Is 178 Coolidge Hill covered by BEUDO?

Yes — it appears in the 2024 Building Energy Use Disclosure Ordinance (BEUDO) disclosure, which lists the buildings reporting under BEUDO.

Working with Cambridge building benchmarking records? Pro adds alerts, change history and CSV export ($49/mo); Enterprise adds full national files, the API and an MCP server for AI tools.

About this data

Source: Building Energy Use Disclosure Ordinance (BEUDO) (BEUDO), as published October 2, 2026. See the methodology for how records are matched, cleaned and scored.

Cite as: BuildingCensus, “178 Coolidge Hill, Cambridge, Massachusetts — 2024 benchmarking disclosure”, https://buildingcensus.com/buildings/cambridge/178-coolidge-hill-a5997560 (data as of October 2, 2026).