BuildingCensus
B

Aberdeen

Mixed Use Property in Chicago, IL · 171 N. Aberdeen St · 60607

At a glance

Aberdeen is a 155,000-square-foot mixed use property building at 171 N. Aberdeen St in Chicago, Illinois, built in 2018. In its 2023 Chicago benchmarking disclosure it reported an ENERGY STAR score of 70 out of 100 (grade B), a site energy-use intensity of 66.4 kBtu/ft² and 972 tCO₂e of greenhouse-gas emissions. That score is higher than 55% of the 11 scored mixed use property buildings in Chicago.

ENERGY STAR score
70
band B · 2023
Site EUI
66.4
kBtu/ft²
GHG emissions
972
tCO₂e
GHG intensity
6.3
kgCO₂e/ft²
Floor area
155,000
sq ft
Year built
2018
vintage
◆ Loading map…
85–10070–8455–691–54
This entry + 6 nearby

Building Energy Use Benchmarking Ordinance · reporting year 2023

Benchmarking record

FieldValue
ENERGY STAR score70 (band B)
Site EUI66.4 kBtu/ft²
Source EUI125.0 kBtu/ft²
GHG emissions972 tCO₂e
GHG intensity6.3 kgCO₂e/ft²
Electricity1,433,282 kWh
Natural gas54,083 therms
Gross floor area155,000 sq ft
Source recordchicago:255946:2023

The disclosure history

Year over year

YearScoreΔSite EUIGHG emissions
2023latest7066.4 kBtu/ft²972 tCO₂e
2022———
20217171.9 kBtu/ft²1,008 tCO₂e
2020———
2019———
2018———

Compliance context

Building Energy Use Benchmarking Ordinance

Covered buildings that fail to benchmark and report face fines of up to $100 plus $25 per day of violation under the ordinance.

Program details →

Ownership

No owning organisation shown. Names of private individuals in the disclosure are not published here.

Own or manage this building? Claim it to correct the record and get compliance alerts.

Location

Address
171 N. Aberdeen St
State
Illinois
ZIP
60607
Coordinates
41.91036, -87.69362

Within ~1 km

Nearby benchmarked buildings

See also: most efficient in Chicago · biggest emitters

How does Aberdeen compare with other mixed use property buildings in Chicago?

The latest disclosures cover 40 mixed use property buildings in Chicago, out of 3,852 buildings citywide. Aberdeen's ENERGY STAR score of 70 compares with an average of 59 across the 11 that report a score; it scores higher than 55% of them and lower than 36%. Its site EUI of 66.4 kBtu/ft² is about 32% below the average of 98.2 kBtu/ft² — it uses less energy per square foot than the typical building in that group. Its emissions intensity of 6.3 kgCO₂e/ft² is about 38% below the group average of 10.1 kgCO₂e/ft².

At 155,000 sq ft, it is about 78% below the average floor area of 689,510 sq ft for those buildings. It was built in 2018, 49 years later than the group's average year built (1969). Across all 24 jurisdictions BuildingCensus covers, the 1,212 mixed use property buildings average an ENERGY STAR score of 69 and a site EUI of 79.8 kBtu/ft².

How has Aberdeen's energy performance changed over time?

BuildingCensus holds 6 Chicago disclosures for Aberdeen, covering report years 2018–2023. Its ENERGY STAR score went from 71 in 2021 to 70 in 2023 (-1 points); its best year on file was 2021, at 71. Site EUI moved from 71.9 kBtu/ft² (2021) to 66.4 kBtu/ft² (2023), a 8% decrease. Reported emissions went from 1,008 tCO₂e to 972 tCO₂e over the same span (down 4%).

What does an ENERGY STAR score of 70 mean?

ENERGY STAR scores run from 1 to 100 and are computed by the EPA's Portfolio Manager as a percentile against similar buildings nationwide, adjusted for climate, size and use: a score of 70 means the building performs better than about 70% of its national peers. BuildingCensus bands the score into report-card grades; 70 falls in band B — above median (70–84). It sits 5 points below 75, the threshold for ENERGY STAR certification. In Chicago, 35% of scored buildings are at 75 or above.

Site energy-use intensity (EUI) is the energy a building uses on site in a year divided by its floor area, in thousand Btu per square foot — lower is more efficient. Aberdeen's 66.4 kBtu/ft² across 155,000 sq ft works out to about 10.3 billion Btu (3,016 MWh-equivalent) in 2023. Its source EUI of 125.0 kBtu/ft² also counts the energy lost generating and delivering that power, which is why it is higher. The disclosure also reports 1,433,282 kWh of electricity and 54,083 therms of natural gas for the year.

Which law requires Aberdeen to report its energy use?

Aberdeen reports under the Building Energy Use Benchmarking Ordinance, the legal basis of the Chicago Energy Benchmarking program, which publishes each covered building's annual benchmarking results. The record shown here is the report-year 2023 disclosure (source record chicago:255946:2023). Covered buildings that fail to benchmark and report face fines of up to $100 plus $25 per day of violation under the ordinance.

More mixed use property buildings in Chicago

Frequently asked questions

What is Aberdeen's energy grade?

Aberdeen scores 70 out of 100 on ENERGY STAR — band B, above median (70–84) — in its 2023 Chicago disclosure. Scores are national percentiles against similar buildings; 75+ qualifies for ENERGY STAR certification.

How much energy does Aberdeen use?

Its 2023 site energy-use intensity was 66.4 kBtu/ft² (125.0 kBtu/ft² source) across 155,000 sq ft, including 1,433,282 kWh of electricity and 54,083 therms of natural gas.

What are Aberdeen's carbon emissions?

Aberdeen reported 972 tCO₂e of greenhouse-gas emissions (6.3 kgCO₂e/ft²) for 2023.

Where is Aberdeen?

Aberdeen is at 171 N. Aberdeen St, in Chicago, Illinois 60607. Its coordinates are 41.91036, -87.69362 (latitude, longitude), as published in the Chicago Energy Benchmarking file.

How big is Aberdeen and when was it built?

Aberdeen has 155,000 sq ft of gross floor area, as reported in its 2023 disclosure. The disclosure lists 2018 as its year built. It is classed as mixed use property.

Is Aberdeen covered by the Building Energy Use Benchmarking Ordinance?

Yes — it appears in the 2023 Chicago Energy Benchmarking disclosure, which lists the buildings reporting under the Building Energy Use Benchmarking Ordinance.

Working with Chicago building benchmarking records? Pro adds alerts, change history and CSV export ($49/mo); Enterprise adds full national files, the API and an MCP server for AI tools.

About this data

Source: Chicago Energy Benchmarking (Building Energy Use Benchmarking Ordinance), as published October 2, 2026. See the methodology for how records are matched, cleaned and scored.

Cite as: BuildingCensus, “Aberdeen, Chicago, Illinois — 2023 benchmarking disclosure”, https://buildingcensus.com/buildings/chicago/aberdeen-e2ee0593 (data as of October 2, 2026).