BuildingCensus
D

Francis W Parker School - Main Building

K-12 School in Chicago, IL · 330 W Webster Ave · 60614

ENERGY STAR score
35
band D · 2023
Site EUI
61.1
kBtu/ft²
GHG emissions
1,850
tCO₂e
GHG intensity
7.9
kgCO₂e/ft²
Floor area
233,000
sq ft
Year built
2000
vintage
◆ Loading map…
85–10070–8455–691–54
This entry + 6 nearby

Building Energy Use Benchmarking Ordinance · reporting year 2023

Benchmarking record

FieldValue
ENERGY STAR score35 (band D)
Site EUI61.1 kBtu/ft²
Source EUI158.8 kBtu/ft²
GHG emissions1,850 tCO₂e
GHG intensity7.9 kgCO₂e/ft²
Electricity3,689,726 kWh
Natural gas16,553 therms
Gross floor area233,000 sq ft
Source recordchicago:173719:2023

The disclosure history

Year over year

YearScoreΔSite EUIGHG emissions
2023latest35+2461.1 kBtu/ft²1,850 tCO₂e
202211+4113.5 kBtu/ft²2,423 tCO₂e
20217-5158.0 kBtu/ft²2,721 tCO₂e
202012+5105.7 kBtu/ft²2,557 tCO₂e
20197-3121.3 kBtu/ft²3,033 tCO₂e
201810+1114.5 kBtu/ft²2,948 tCO₂e
20179±0104.9 kBtu/ft²3,063 tCO₂e
20169105.7 kBtu/ft²3,125 tCO₂e

Compliance context

Building Energy Use Benchmarking Ordinance

Covered buildings that fail to benchmark and report face fines of up to $100 plus $25 per day of violation under the ordinance.

Program details →

Ownership

No owning organisation shown. Names of private individuals in the disclosure are not published here.

Own or manage this building? Claim it to correct the record and get compliance alerts.

Location

Address
330 W Webster Ave
State
Illinois
ZIP
60614
Coordinates
41.85965, -87.62066

Within ~1 km

Nearby benchmarked buildings

See also: most efficient in Chicago · biggest emitters

Frequently asked questions

What is Francis W Parker School - Main Building's energy grade?

Francis W Parker School - Main Building scores 35 out of 100 on ENERGY STAR — band D (Lowest band (1–54)) — in its 2023 Chicago disclosure. Scores are national percentiles against similar buildings; 75+ qualifies for ENERGY STAR certification.

How much energy does Francis W Parker School - Main Building use?

Its 2023 site energy-use intensity was 61.1 kBtu/ft² (158.8 kBtu/ft² source) across 233,000 sq ft, including 3,689,726 kWh of electricity and 16,553 therms of natural gas.

What are Francis W Parker School - Main Building's carbon emissions?

Francis W Parker School - Main Building reported 1,850 tCO₂e of greenhouse-gas emissions (7.9 kgCO₂e/ft²) for 2023. Covered buildings that fail to benchmark and report face fines of up to $100 plus $25 per day of violation under the ordinance.

Working with Chicago building benchmarking records? Pro adds alerts, change history and CSV export ($49/mo); Enterprise adds full national files, the API and an MCP server for AI tools.

Dataset updated . Source: Chicago Energy Benchmarking disclosure, record chicago:173719:2023.