BuildingCensus
D

Penn ES / Kipp Ascend

K-12 School in Chicago, IL · 1616 S Avers Ave · 60623

At a glance

Penn ES / Kipp Ascend is a 158,325-square-foot K-12 school at 1616 S Avers Ave in Chicago, Illinois, built in 1907. In its 2023 Chicago benchmarking disclosure it reported an ENERGY STAR score of 37 out of 100 (grade D), a site energy-use intensity of 82.2 kBtu/ft² and 976 tCO₂e of greenhouse-gas emissions. That score is higher than 41% of the 365 scored K-12 school buildings in Chicago.

ENERGY STAR score
37
band D · 2023
Site EUI
82.2
kBtu/ft²
GHG emissions
976
tCO₂e
GHG intensity
6.2
kgCO₂e/ft²
Floor area
158,325
sq ft
Year built
1907
vintage
◆ Loading map…
85–10070–8455–691–54
This entry + 2 nearby

Building Energy Use Benchmarking Ordinance · reporting year 2023

Benchmarking record

FieldValue
ENERGY STAR score37 (band D)
Site EUI82.2 kBtu/ft²
Source EUI122.6 kBtu/ft²
GHG emissions976 tCO₂e
GHG intensity6.2 kgCO₂e/ft²
Electricity959,828 kWh
Natural gas97,466 therms
Gross floor area158,325 sq ft
Source recordchicago:251712:2023

The disclosure history

Year over year

YearScoreΔSite EUIGHG emissions
2023latest3782.2 kBtu/ft²976 tCO₂e
2022———
2021———
20205870.0 kBtu/ft²892 tCO₂e
2019———
2018———

Compliance context

Building Energy Use Benchmarking Ordinance

Covered buildings that fail to benchmark and report face fines of up to $100 plus $25 per day of violation under the ordinance.

Program details →

Ownership

No owning organisation shown. Names of private individuals in the disclosure are not published here.

Own or manage this building? Claim it to correct the record and get compliance alerts.

Location

Address
1616 S Avers Ave
State
Illinois
ZIP
60623
Coordinates
41.72151, -87.64860

Within ~1 km

Nearby benchmarked buildings

See also: most efficient in Chicago · biggest emitters

How does Penn ES / Kipp Ascend compare with other K-12 school buildings in Chicago?

The latest disclosures cover 543 K-12 school buildings in Chicago, out of 3,852 buildings citywide. Penn ES / Kipp Ascend's ENERGY STAR score of 37 compares with an average of 45 across the 365 that report a score; it scores higher than 41% of them and lower than 58%. Its site EUI of 82.2 kBtu/ft² is about 13% above the average of 72.7 kBtu/ft² — it uses more energy per square foot than the typical building in that group. Its emissions intensity of 6.2 kgCO₂e/ft² is roughly in line with the group average of 6.2 kgCO₂e/ft².

At 158,325 sq ft, it is about 30% above the average floor area of 121,824 sq ft for those buildings. It was built in 1907, 36 years earlier than the group's average year built (1943). Across all 24 jurisdictions BuildingCensus covers, the 6,548 K-12 school buildings average an ENERGY STAR score of 64 and a site EUI of 52.7 kBtu/ft².

How has Penn ES / Kipp Ascend's energy performance changed over time?

BuildingCensus holds 6 Chicago disclosures for Penn ES / Kipp Ascend, covering report years 2018–2023. Its ENERGY STAR score went from 58 in 2020 to 37 in 2023 (-21 points); its best year on file was 2020, at 58. Site EUI moved from 70.0 kBtu/ft² (2020) to 82.2 kBtu/ft² (2023), an 17% increase. Reported emissions went from 892 tCO₂e to 976 tCO₂e over the same span (up 9%).

What does an ENERGY STAR score of 37 mean?

ENERGY STAR scores run from 1 to 100 and are computed by the EPA's Portfolio Manager as a percentile against similar buildings nationwide, adjusted for climate, size and use: a score of 37 means the building performs better than about 37% of its national peers. BuildingCensus bands the score into report-card grades; 37 falls in band D — lowest band (1–54). It sits 38 points below 75, the threshold for ENERGY STAR certification. In Chicago, 35% of scored buildings are at 75 or above.

Site energy-use intensity (EUI) is the energy a building uses on site in a year divided by its floor area, in thousand Btu per square foot — lower is more efficient. Penn ES / Kipp Ascend's 82.2 kBtu/ft² across 158,325 sq ft works out to about 13 billion Btu (3,814 MWh-equivalent) in 2023. Its source EUI of 122.6 kBtu/ft² also counts the energy lost generating and delivering that power, which is why it is higher. The disclosure also reports 959,828 kWh of electricity and 97,466 therms of natural gas for the year.

Which law requires Penn ES / Kipp Ascend to report its energy use?

Penn ES / Kipp Ascend reports under the Building Energy Use Benchmarking Ordinance, the legal basis of the Chicago Energy Benchmarking program, which publishes each covered building's annual benchmarking results. The record shown here is the report-year 2023 disclosure (source record chicago:251712:2023). Covered buildings that fail to benchmark and report face fines of up to $100 plus $25 per day of violation under the ordinance.

More K-12 school buildings in Chicago

Frequently asked questions

What is Penn ES / Kipp Ascend's energy grade?

Penn ES / Kipp Ascend scores 37 out of 100 on ENERGY STAR — band D, lowest band (1–54) — in its 2023 Chicago disclosure. Scores are national percentiles against similar buildings; 75+ qualifies for ENERGY STAR certification.

How much energy does Penn ES / Kipp Ascend use?

Its 2023 site energy-use intensity was 82.2 kBtu/ft² (122.6 kBtu/ft² source) across 158,325 sq ft, including 959,828 kWh of electricity and 97,466 therms of natural gas.

What are Penn ES / Kipp Ascend's carbon emissions?

Penn ES / Kipp Ascend reported 976 tCO₂e of greenhouse-gas emissions (6.2 kgCO₂e/ft²) for 2023.

Where is Penn ES / Kipp Ascend?

Penn ES / Kipp Ascend is at 1616 S Avers Ave, in Chicago, Illinois 60623. Its coordinates are 41.72151, -87.64860 (latitude, longitude), as published in the Chicago Energy Benchmarking file.

How big is Penn ES / Kipp Ascend and when was it built?

Penn ES / Kipp Ascend has 158,325 sq ft of gross floor area, as reported in its 2023 disclosure. The disclosure lists 1907 as its year built. It is classed as K-12 school.

Is Penn ES / Kipp Ascend covered by the Building Energy Use Benchmarking Ordinance?

Yes — it appears in the 2023 Chicago Energy Benchmarking disclosure, which lists the buildings reporting under the Building Energy Use Benchmarking Ordinance.

Working with Chicago building benchmarking records? Pro adds alerts, change history and CSV export ($49/mo); Enterprise adds full national files, the API and an MCP server for AI tools.

About this data

Source: Chicago Energy Benchmarking (Building Energy Use Benchmarking Ordinance), as published October 2, 2026. See the methodology for how records are matched, cleaned and scored.

Cite as: BuildingCensus, “Penn ES / Kipp Ascend, Chicago, Illinois — 2023 benchmarking disclosure”, https://buildingcensus.com/buildings/chicago/penn-es-kipp-ascend-8f864e5e (data as of October 2, 2026).