BuildingCensus
D

Public Safety Building

Office in California, CA · 1245 03Rd St, San Francisco · 94158

At a glance

Public Safety Building is a 185,855-square-foot office building at 1245 03Rd St, San Francisco in San Francisco, California, built in 2000. In its 2022 California benchmarking disclosure it reported an ENERGY STAR score of 53 out of 100 (grade D), a site energy-use intensity of 89.7 kBtu/ft² and 1,063 tCO₂e of greenhouse-gas emissions. That score is higher than 17% of the 4,912 scored office buildings in California.

ENERGY STAR score
53
band D · 2022
Site EUI
89.7
kBtu/ft²
GHG emissions
1,063
tCO₂e
GHG intensity
5.7
kgCO₂e/ft²
Floor area
185,855
sq ft
Year built
2000
vintage
◆ Loading map…
85–10070–8455–691–54
This entry + 6 nearby

AB 802 (Public Resources Code §25402.10) · reporting year 2022

Benchmarking record

FieldValue
ENERGY STAR score53 (band D)
Site EUI89.7 kBtu/ft²
Source EUI—
GHG emissions1,063 tCO₂e
GHG intensity5.7 kgCO₂e/ft²
Electricity2,787,586 kWh
Natural gas73,177 therms
Gross floor area185,855 sq ft
Source recordcalifornia:11286093:2022

The disclosure history

Year over year

YearScoreΔSite EUIGHG emissions
2022latest5389.7 kBtu/ft²1,063 tCO₂e
2020—191.1 kBtu/ft²878 tCO₂e
2019—201.5 kBtu/ft²924 tCO₂e

Compliance context

AB 802 (Public Resources Code §25402.10)

AB 802 requires every California commercial building over 50,000 sq ft to report energy use to the CEC annually; the CEC publicly discloses the results statewide.

Program details →

Ownership

No owning organisation shown. Names of private individuals in the disclosure are not published here.

Own or manage this building? Claim it to correct the record and get compliance alerts.

Location

Address
1245 03Rd St, San Francisco
State
California
ZIP
94158
Coordinates
37.77260, -122.38927

Within ~1 km

Nearby benchmarked buildings

See also: most efficient in California · biggest emitters

How does Public Safety Building compare with other office buildings in California?

The latest disclosures cover 6,214 office buildings in California, out of 40,029 buildings citywide. Public Safety Building's ENERGY STAR score of 53 compares with an average of 75 across the 4,912 that report a score; it scores higher than 17% of them and lower than 82%. Its site EUI of 89.7 kBtu/ft² is about 59% above the average of 56.4 kBtu/ft² — it uses more energy per square foot than the typical building in that group. Its emissions intensity of 5.7 kgCO₂e/ft² is about 58% above the group average of 3.6 kgCO₂e/ft².

At 185,855 sq ft, it is about 22% above the average floor area of 151,937 sq ft for those buildings. It was built in 2000, 15 years later than the group's average year built (1985). Across all 24 jurisdictions BuildingCensus covers, the 15,264 office buildings average an ENERGY STAR score of 73 and a site EUI of 59.3 kBtu/ft².

How has Public Safety Building's energy performance changed over time?

BuildingCensus holds 3 California disclosures for Public Safety Building, covering report years 2019, 2020, 2022. Site EUI moved from 201.5 kBtu/ft² (2019) to 89.7 kBtu/ft² (2022), a 55% decrease. Reported emissions went from 924 tCO₂e to 1,063 tCO₂e over the same span (up 15%).

What does an ENERGY STAR score of 53 mean?

ENERGY STAR scores run from 1 to 100 and are computed by the EPA's Portfolio Manager as a percentile against similar buildings nationwide, adjusted for climate, size and use: a score of 53 means the building performs better than about 53% of its national peers. BuildingCensus bands the score into report-card grades; 53 falls in band D — lowest band (1–54). It sits 22 points below 75, the threshold for ENERGY STAR certification. In California, 65% of scored buildings are at 75 or above.

Site energy-use intensity (EUI) is the energy a building uses on site in a year divided by its floor area, in thousand Btu per square foot — lower is more efficient. Public Safety Building's 89.7 kBtu/ft² across 185,855 sq ft works out to about 16.7 billion Btu (4,886 MWh-equivalent) in 2022. The disclosure also reports 2,787,586 kWh of electricity and 73,177 therms of natural gas for the year.

Which law requires Public Safety Building to report its energy use?

Public Safety Building reports under AB 802 (Public Resources Code §25402.10), the legal basis of California's Building Energy Benchmarking Program (statewide), which publishes each covered building's annual benchmarking results. The record shown here is the report-year 2022 disclosure (source record california:11286093:2022). AB 802 requires every California commercial building over 50,000 sq ft to report energy use to the CEC annually; the CEC publicly discloses the results statewide.

More office buildings in California

Frequently asked questions

What is Public Safety Building's energy grade?

Public Safety Building scores 53 out of 100 on ENERGY STAR — band D, lowest band (1–54) — in its 2022 California disclosure. Scores are national percentiles against similar buildings; 75+ qualifies for ENERGY STAR certification.

How much energy does Public Safety Building use?

Its 2022 site energy-use intensity was 89.7 kBtu/ft² across 185,855 sq ft, including 2,787,586 kWh of electricity and 73,177 therms of natural gas.

What are Public Safety Building's carbon emissions?

Public Safety Building reported 1,063 tCO₂e of greenhouse-gas emissions (5.7 kgCO₂e/ft²) for 2022.

Where is Public Safety Building?

Public Safety Building is at 1245 03Rd St, San Francisco, in San Francisco, California 94158. Its coordinates are 37.77260, -122.38927 (latitude, longitude), as published in the Building Energy Benchmarking Program (statewide) file.

How big is Public Safety Building and when was it built?

Public Safety Building has 185,855 sq ft of gross floor area, as reported in its 2022 disclosure. The disclosure lists 2000 as its year built. It is classed as office.

Is Public Safety Building covered by AB 802 (Public Resources Code §25402.10)?

Yes — it appears in the 2022 Building Energy Benchmarking Program (statewide) disclosure, which lists the buildings reporting under AB 802 (Public Resources Code §25402.10).

Working with California building benchmarking records? Pro adds alerts, change history and CSV export ($49/mo); Enterprise adds full national files, the API and an MCP server for AI tools.

About this data

Source: Building Energy Benchmarking Program (statewide) (AB 802 (Public Resources Code §25402.10)), as published July 9, 2026. See the methodology for how records are matched, cleaned and scored.

Cite as: BuildingCensus, “Public Safety Building, San Francisco, California — 2022 benchmarking disclosure”, https://buildingcensus.com/buildings/california/public-safety-building-f5948270 (data as of July 9, 2026).