BuildingCensus
A

Irving Park Middle -CPS

K-12 School in Chicago, IL · 3815 N Kedvale Ave · 60641

ENERGY STAR score
95
band A · 2022
Site EUI
29.0
kBtu/ft²
GHG emissions
501
tCO₂e
GHG intensity
2.4
kgCO₂e/ft²
Floor area
207,520
sq ft
Year built
1906
vintage
◆ Loading map…
85–10070–8455–691–54
This entry + 6 nearby

Building Energy Use Benchmarking Ordinance · reporting year 2022

Benchmarking record

FieldValue
ENERGY STAR score95 (band A)
Site EUI29.0 kBtu/ft²
Source EUI49.9 kBtu/ft²
GHG emissions501 tCO₂e
GHG intensity2.4 kgCO₂e/ft²
Electricity674,672 kWh
Natural gas37,230 therms
Gross floor area207,520 sq ft
Source recordchicago:251358:2022

The disclosure history

Year over year

YearScoreΔSite EUIGHG emissions
2022latest95+7629.0 kBtu/ft²501 tCO₂e
202119-2291.4 kBtu/ft²411 tCO₂e
20204168.2 kBtu/ft²349 tCO₂e
2019———
201827-181.4 kBtu/ft²445 tCO₂e
201728+585.6 kBtu/ft²506 tCO₂e
201623+688.6 kBtu/ft²540 tCO₂e
20151796.9 kBtu/ft²607 tCO₂e

Compliance context

Building Energy Use Benchmarking Ordinance

Covered buildings that fail to benchmark and report face fines of up to $100 plus $25 per day of violation under the ordinance.

Program details →

Ownership

No owning organisation shown. Names of private individuals in the disclosure are not published here.

Own or manage this building? Claim it to correct the record and get compliance alerts.

Location

Address
3815 N Kedvale Ave
State
Illinois
ZIP
60641
Coordinates
41.95048, -87.73061

Within ~1 km

Nearby benchmarked buildings

See also: most efficient in Chicago · biggest emitters

Frequently asked questions

What is Irving Park Middle -CPS's energy grade?

Irving Park Middle -CPS scores 95 out of 100 on ENERGY STAR — band A (High performer (85–100)) — in its 2022 Chicago disclosure. Scores are national percentiles against similar buildings; 75+ qualifies for ENERGY STAR certification.

How much energy does Irving Park Middle -CPS use?

Its 2022 site energy-use intensity was 29.0 kBtu/ft² (49.9 kBtu/ft² source) across 207,520 sq ft, including 674,672 kWh of electricity and 37,230 therms of natural gas.

What are Irving Park Middle -CPS's carbon emissions?

Irving Park Middle -CPS reported 501 tCO₂e of greenhouse-gas emissions (2.4 kgCO₂e/ft²) for 2022. Covered buildings that fail to benchmark and report face fines of up to $100 plus $25 per day of violation under the ordinance.

Working with Chicago building benchmarking records? Pro adds alerts, change history and CSV export ($49/mo); Enterprise adds full national files, the API and an MCP server for AI tools.

Dataset updated . Source: Chicago Energy Benchmarking disclosure, record chicago:251358:2022.