BuildingCensus
–

100 N DOHENY DR

Multifamily Housing in Los Angeles, CA · 90048

ENERGY STAR score
—
not reported · 2025
Site EUI
29.8
kBtu/ft²
GHG emissions
38
tCO₂e
GHG intensity
—
kgCO₂e/ft²
Floor area
23,493
sq ft
Year built
1972
vintage

LA Municipal Code Div. 97, §91.9701 (EBEWE) · reporting year 2025

Benchmarking record

FieldValue
ENERGY STAR score—
Site EUI29.8 kBtu/ft²
Source EUI53.9 kBtu/ft²
GHG emissions38 tCO₂e
GHG intensity—
Water use704 kgal
Gross floor area23,493 sq ft
Source recordla:443718850076:2025

The disclosure history

Year over year

YearScoreΔSite EUIGHG emissions
2025latest—29.8 kBtu/ft²38 tCO₂e
2024—28.7 kBtu/ft²37 tCO₂e
2023—28.7 kBtu/ft²41 tCO₂e
2022—28.0 kBtu/ft²40 tCO₂e
2021—29.9 kBtu/ft²42 tCO₂e
2020—30.3 kBtu/ft²43 tCO₂e
2019—32.3 kBtu/ft²47 tCO₂e
2018—28.2 kBtu/ft²41 tCO₂e

Compliance context

LA Municipal Code Div. 97, §91.9701 (EBEWE)

EBEWE requires annual benchmarking plus audits/retro-commissioning every five years for privately owned buildings of 20,000 sq ft or more; non-compliance carries a $202 fee (LAMC §91.9712) plus possible late fees.

Program details →

Ownership

No owning organisation shown. Names of private individuals in the disclosure are not published here.

Own or manage this building? Claim it to correct the record and get compliance alerts.

Location

Address
100 N DOHENY DR
State
California
ZIP
90048

Within ~1 km

Nearby benchmarked buildings

This source publishes no coordinates, so nearby buildings can't be resolved yet.

See also: most efficient in Los Angeles · biggest emitters

Frequently asked questions

What is 100 N DOHENY DR's energy grade?

100 N DOHENY DR did not report an ENERGY STAR score in its 2025 disclosure, but its site energy-use intensity was 29.8 kBtu/ft².

How much energy does 100 N DOHENY DR use?

Its 2025 site energy-use intensity was 29.8 kBtu/ft² (53.9 kBtu/ft² source) across 23,493 sq ft.

What are 100 N DOHENY DR's carbon emissions?

100 N DOHENY DR reported 38 tCO₂e of greenhouse-gas emissions for 2025. EBEWE requires annual benchmarking plus audits/retro-commissioning every five years for privately owned buildings of 20,000 sq ft or more; non-compliance carries a $202 fee (LAMC §91.9712) plus possible late fees.

Working with Los Angeles building benchmarking records? Pro adds alerts, change history and CSV export ($49/mo); Enterprise adds full national files, the API and an MCP server for AI tools.

Dataset updated . Source: Existing Buildings Energy & Water Efficiency (EBEWE) disclosure, record la:443718850076:2025.