290 DIVISION ST
Commercial in San Francisco, CA · 94103
SF Environment Code Chapter 20 · reporting year 2025
Benchmarking record
| Field | Value |
|---|---|
| ENERGY STAR score | — |
| Site EUI | 28.9 kBtu/ft² |
| Source EUI | 59.1 kBtu/ft² |
| GHG emissions | 57 tCO₂e |
| GHG intensity | 1.6 kgCO₂e/ft² |
| Electricity | 171,931 kWh |
| Natural gas | 4,413 therms |
| Gross floor area | 35,628 sq ft |
| Source record | sf:3526/016:2025 |
The disclosure history
Year over year
| Year | Score | Δ | Site EUI | GHG emissions |
|---|---|---|---|---|
| 2025latest | — | 28.9 kBtu/ft² | 57 tCO₂e | |
| 2024 | — | 18.0 kBtu/ft² | 41 tCO₂e | |
| 2023 | — | 20.6 kBtu/ft² | 50 tCO₂e | |
| 2022 | — | — | — | |
| 2021 | — | — | — | |
| 2020 | — | — | — | |
| 2019 | — | — | — | |
| 2018 | — | — | — | |
| 2017 | — | — | — | |
| 2016 | — | — | — | |
| 2015 | — | — | — | |
| 2014 | — | — | — | |
| 2013 | — | — | — | |
| 2012 | — | — | — | |
| 2011 | — | — | — |
Compliance context
SF Environment Code Chapter 20
San Francisco's ordinance requires annual benchmarking for commercial buildings over 10,000 sq ft, with administrative penalties for buildings that fail to report.
Ownership
No owner listed in the disclosure.
Own or manage this building? Claim it to correct the record and get compliance alerts.
Location
- Address
- 290 DIVISION ST
- City
- San Francisco
- State
- California
- ZIP
- 94103
- Coordinates
- 37.76951, -122.40826
Within ~1 km
Nearby benchmarked buildings
- 650 Townsend - Zyngascore —
Commercial · 1,029,659 sq ft
- 650 Townsendscore 97
Office · 872,484 sq ft
- 1201 Bryant Streetscore 100
Office · 805,178 sq ft
- 625 08TH STscore —
Multifamily · 641,987 sq ft
- Hall Of Justicescore 39
Office · 634,717 sq ft
- 855 Brannan - 29928score 98
Multifamily Housing · 500,569 sq ft
See also: most efficient in San Francisco · biggest emitters
Frequently asked questions
What is 290 DIVISION ST's energy grade?
290 DIVISION ST did not report an ENERGY STAR score in its 2025 disclosure, but its site energy-use intensity was 28.9 kBtu/ft².
How much energy does 290 DIVISION ST use?
Its 2025 site energy-use intensity was 28.9 kBtu/ft² (59.1 kBtu/ft² source) across 35,628 sq ft, including 171,931 kWh of electricity and 4,413 therms of natural gas.
What are 290 DIVISION ST's carbon emissions?
290 DIVISION ST reported 57 tCO₂e of greenhouse-gas emissions (1.6 kgCO₂e/ft²) for 2025. San Francisco's ordinance requires annual benchmarking for commercial buildings over 10,000 sq ft, with administrative penalties for buildings that fail to report.
Dataset updated . Source: Existing Buildings Energy Performance Ordinance disclosure, record sf:3526/016:2025.