BuildingCensus
–

Jeffrey Modell Immunology Center

College/University in Boston, MA · 2115.

At a glance

Jeffrey Modell Immunology Center is a 7,000-square-foot college/university building in Boston, Massachusetts. In its 2024 Boston benchmarking disclosure it reported a site energy-use intensity of 238.6 kBtu/ft² and 97 tCO₂e of greenhouse-gas emissions.

ENERGY STAR score
—
not reported · 2024
Site EUI
238.6
kBtu/ft²
GHG emissions
97
tCO₂e
GHG intensity
—
kgCO₂e/ft²
Floor area
7,000
sq ft
Year built
—
vintage

BERDO 2.0 · reporting year 2024

Benchmarking record

FieldValue
ENERGY STAR score—
Site EUI238.6 kBtu/ft²
Source EUI—
GHG emissions97 tCO₂e
GHG intensity—
Electricity93,908 kWh
Gross floor area7,000 sq ft
Source recordboston:107134:2024

The disclosure history

Year over year

YearScoreΔSite EUIGHG emissions
2024latest—238.6 kBtu/ft²97 tCO₂e
2023—276.8 kBtu/ft²124 tCO₂e
2022—214.7 kBtu/ft²91 tCO₂e

Compliance context

BERDO 2.0

BERDO 2.0 sets emissions standards for buildings of 20,000+ sq ft or 15+ units, starting in 2025 or 2030 depending on building size, with an alternative-compliance payment of $234 per metric ton of CO₂e over the limit.

Program details →

Ownership

PRESIDENT AND FELLOWS OF HARVARD COLLEGE

Own or manage this building? Claim it to correct the record and get compliance alerts.

Location

Address
Jeffrey Modell Immunology Center
City
Boston
State
Massachusetts
ZIP
2115.

Within ~1 km

Nearby benchmarked buildings

This source publishes no coordinates, so nearby buildings can't be resolved yet.

See also: most efficient in Boston · biggest emitters

How does Jeffrey Modell Immunology Center compare with other college/university buildings in Boston?

The latest disclosures cover 316 college/university buildings in Boston, out of 6,305 buildings citywide. Its site EUI of 238.6 kBtu/ft² is about 175% above the average of 86.9 kBtu/ft² — it uses more energy per square foot than the typical building in that group.

At 7,000 sq ft, it is about 96% below the average floor area of 195,557 sq ft for those buildings. Across all 24 jurisdictions BuildingCensus covers, the 2,113 college/university buildings average an ENERGY STAR score of 68 and a site EUI of 98.7 kBtu/ft².

How has Jeffrey Modell Immunology Center's energy performance changed over time?

BuildingCensus holds 3 Boston disclosures for Jeffrey Modell Immunology Center, covering report years 2022–2024. Site EUI moved from 214.7 kBtu/ft² (2022) to 238.6 kBtu/ft² (2024), an 11% increase. Reported emissions went from 91 tCO₂e to 97 tCO₂e over the same span (up 7%).

What does a site EUI of 238.6 kBtu/ft² mean?

Site energy-use intensity (EUI) is the energy a building uses on site in a year divided by its floor area, in thousand Btu per square foot — lower is more efficient. Jeffrey Modell Immunology Center's 238.6 kBtu/ft² across 7,000 sq ft works out to about 1.7 billion Btu (489 MWh-equivalent) in 2024. The disclosure also reports 93,908 kWh of electricity for the year.

Which law requires Jeffrey Modell Immunology Center to report its energy use?

Jeffrey Modell Immunology Center reports under BERDO 2.0, the legal basis of Boston's Building Emissions Reduction and Disclosure Ordinance, which publishes each covered building's annual benchmarking results. The record shown here is the report-year 2024 disclosure (source record boston:107134:2024). BERDO 2.0 sets emissions standards for buildings of 20,000+ sq ft or 15+ units, starting in 2025 or 2030 depending on building size, with an alternative-compliance payment of $234 per metric ton of CO₂e over the limit.

More college/university buildings in Boston

Frequently asked questions

What is Jeffrey Modell Immunology Center's energy grade?

Jeffrey Modell Immunology Center did not report an ENERGY STAR score in its 2024 disclosure, but its site energy-use intensity was 238.6 kBtu/ft².

How much energy does Jeffrey Modell Immunology Center use?

Its 2024 site energy-use intensity was 238.6 kBtu/ft² across 7,000 sq ft, including 93,908 kWh of electricity.

What are Jeffrey Modell Immunology Center's carbon emissions?

Jeffrey Modell Immunology Center reported 97 tCO₂e of greenhouse-gas emissions for 2024.

Where is Jeffrey Modell Immunology Center?

Jeffrey Modell Immunology Center is in Boston, Massachusetts 2115.

How big is Jeffrey Modell Immunology Center and when was it built?

Jeffrey Modell Immunology Center has 7,000 sq ft of gross floor area, as reported in its 2024 disclosure. It is classed as college/university.

Is Jeffrey Modell Immunology Center covered by BERDO 2.0?

Yes — it appears in the 2024 Building Emissions Reduction and Disclosure Ordinance disclosure, which lists the buildings reporting under BERDO 2.0.

Working with Boston building benchmarking records? Pro adds alerts, change history and CSV export ($49/mo); Enterprise adds full national files, the API and an MCP server for AI tools.

About this data

Source: Building Emissions Reduction and Disclosure Ordinance (BERDO 2.0), as published July 9, 2026. See the methodology for how records are matched, cleaned and scored.

Cite as: BuildingCensus, “Jeffrey Modell Immunology Center, Boston, Massachusetts — 2024 benchmarking disclosure”, https://buildingcensus.com/buildings/boston/jeffrey-modell-immunology-center-acdde70a (data as of July 9, 2026).