BuildingCensus
D

1301 RYAWA AVENUE

Non-Refrigerated Warehouse in New York City, NY · 10474

At a glance

1301 RYAWA AVENUE is a 120,775-square-foot non-refrigerated warehouse in New York City, New York, built in 1963. In its 2024 New York City benchmarking disclosure it reported an ENERGY STAR score of 17 out of 100 (grade D), a site energy-use intensity of 78.7 kBtu/ft² and 743 tCO₂e of greenhouse-gas emissions. That score is higher than 13% of the 455 scored non-refrigerated warehouse buildings in New York City.

ENERGY STAR score
17
band D · 2024
Site EUI
78.7
kBtu/ft²
GHG emissions
743
tCO₂e
GHG intensity
6.2
kgCO₂e/ft²
Floor area
120,775
sq ft
Year built
1963
vintage
◆ Loading map…
85–10070–8455–691–54
This entry + 6 nearby

Local Law 84 (LL84) · reporting year 2024

Benchmarking record

FieldValue
ENERGY STAR score17 (band D)
Site EUI78.7 kBtu/ft²
Source EUI118.7 kBtu/ft²
GHG emissions743 tCO₂e
GHG intensity6.2 kgCO₂e/ft²
Electricity739,524 kWh
Natural gas56,623 therms
Gross floor area120,775 sq ft
Source recordnyc:24691974:2024

The disclosure history

Year over year

YearScoreΔSite EUIGHG emissions
2024latest17-278.7 kBtu/ft²743 tCO₂e
202319-2864.9 kBtu/ft²587 tCO₂e
20224731.4 kBtu/ft²284 tCO₂e

Compliance context

Local Law 84 (LL84)

Under Local Law 97, buildings over 25,000 sq ft face carbon caps with fines of $268 per metric ton of CO₂e over the limit, phasing in from 2024.

Program details →

Ownership

No owning organisation shown. Names of private individuals in the disclosure are not published here.

Own or manage this building? Claim it to correct the record and get compliance alerts.

Location

Address
1301 RYAWA AVENUE
State
New York
ZIP
10474
Coordinates
40.80498, -73.88384

Within ~1 km

Nearby benchmarked buildings

See also: most efficient in New York City · biggest emitters

How does 1301 RYAWA AVENUE compare with other non-refrigerated warehouse buildings in New York City?

The latest disclosures cover 639 non-refrigerated warehouse buildings in New York City, out of 48,310 buildings citywide. 1301 RYAWA AVENUE's ENERGY STAR score of 17 compares with an average of 57 across the 455 that report a score; it scores higher than 13% of them and lower than 87%. Its site EUI of 78.7 kBtu/ft² is about twice the average of 39.3 kBtu/ft² — it uses more energy per square foot than the typical building in that group. Its emissions intensity of 6.2 kgCO₂e/ft² is about twice the group average of 3.1 kgCO₂e/ft².

At 120,775 sq ft, it is about 45% above the average floor area of 83,240 sq ft for those buildings. It was built in 1963, 10 years later than the group's average year built (1953). Across all 24 jurisdictions BuildingCensus covers, the 4,723 non-refrigerated warehouse buildings average an ENERGY STAR score of 66 and a site EUI of 26.0 kBtu/ft².

How has 1301 RYAWA AVENUE's energy performance changed over time?

BuildingCensus holds 3 New York City disclosures for 1301 RYAWA AVENUE, covering report years 2022–2024. Its ENERGY STAR score went from 47 in 2022 to 17 in 2024 (-30 points); its best year on file was 2022, at 47. Site EUI moved from 31.4 kBtu/ft² (2022) to 78.7 kBtu/ft² (2024), an 151% increase. Reported emissions went from 284 tCO₂e to 743 tCO₂e over the same span (up 161%).

What does an ENERGY STAR score of 17 mean?

ENERGY STAR scores run from 1 to 100 and are computed by the EPA's Portfolio Manager as a percentile against similar buildings nationwide, adjusted for climate, size and use: a score of 17 means the building performs better than about 17% of its national peers. BuildingCensus bands the score into report-card grades; 17 falls in band D — lowest band (1–54). It sits 58 points below 75, the threshold for ENERGY STAR certification. In New York City, 43% of scored buildings are at 75 or above.

Site energy-use intensity (EUI) is the energy a building uses on site in a year divided by its floor area, in thousand Btu per square foot — lower is more efficient. 1301 RYAWA AVENUE's 78.7 kBtu/ft² across 120,775 sq ft works out to about 9.5 billion Btu (2,786 MWh-equivalent) in 2024. Its source EUI of 118.7 kBtu/ft² also counts the energy lost generating and delivering that power, which is why it is higher. The disclosure also reports 739,524 kWh of electricity and 56,623 therms of natural gas for the year.

Which law requires 1301 RYAWA AVENUE to report its energy use?

1301 RYAWA AVENUE reports under Local Law 84 (LL84), the legal basis of New York City's Energy and Water Data Disclosure program, which publishes each covered building's annual benchmarking results. The record shown here is the report-year 2024 disclosure (source record nyc:24691974:2024). Under Local Law 97, buildings over 25,000 sq ft face carbon caps with fines of $268 per metric ton of CO₂e over the limit, phasing in from 2024.

More non-refrigerated warehouse buildings in New York City

Frequently asked questions

What is 1301 RYAWA AVENUE's energy grade?

1301 RYAWA AVENUE scores 17 out of 100 on ENERGY STAR — band D, lowest band (1–54) — in its 2024 New York City disclosure. Scores are national percentiles against similar buildings; 75+ qualifies for ENERGY STAR certification.

How much energy does 1301 RYAWA AVENUE use?

Its 2024 site energy-use intensity was 78.7 kBtu/ft² (118.7 kBtu/ft² source) across 120,775 sq ft, including 739,524 kWh of electricity and 56,623 therms of natural gas.

What are 1301 RYAWA AVENUE's carbon emissions?

1301 RYAWA AVENUE reported 743 tCO₂e of greenhouse-gas emissions (6.2 kgCO₂e/ft²) for 2024.

Where is 1301 RYAWA AVENUE?

1301 RYAWA AVENUE is in New York City, New York 10474. Its coordinates are 40.80498, -73.88384 (latitude, longitude), as published in the Energy and Water Data Disclosure file.

How big is 1301 RYAWA AVENUE and when was it built?

1301 RYAWA AVENUE has 120,775 sq ft of gross floor area, as reported in its 2024 disclosure. The disclosure lists 1963 as its year built. It is classed as non-refrigerated warehouse.

Is 1301 RYAWA AVENUE covered by Local Law 84 (LL84)?

Yes — it appears in the 2024 Energy and Water Data Disclosure disclosure, which lists the buildings reporting under Local Law 84 (LL84).

Working with New York City building benchmarking records? Pro adds alerts, change history and CSV export ($49/mo); Enterprise adds full national files, the API and an MCP server for AI tools.

About this data

Source: Energy and Water Data Disclosure (Local Law 84 (LL84)), as published October 2, 2026. See the methodology for how records are matched, cleaned and scored.

Cite as: BuildingCensus, “1301 RYAWA AVENUE, New York City, New York — 2024 benchmarking disclosure”, https://buildingcensus.com/buildings/new-york-city/1301-ryawa-avenue-87a09fc9 (data as of October 2, 2026).