Benchmarking Group - 119
K-12 School in New York City, NY · 300 Willoughby Ave · 11205
At a glance
Benchmarking Group - 119 is a 176,822-square-foot K-12 school at 300 Willoughby Ave in New York City, New York, built in 1955. In its 2024 New York City benchmarking disclosure it reported an ENERGY STAR score of 78 out of 100 (grade B), a site energy-use intensity of 54.7 kBtu/ft² and 784 tCO₂e of greenhouse-gas emissions. That score is higher than 63% of the 2,052 scored K-12 school buildings in New York City.
Local Law 84 (LL84) · reporting year 2024
Benchmarking record
| Field | Value |
|---|---|
| ENERGY STAR score | 78 (band B) |
| Site EUI | 54.7 kBtu/ft² |
| Source EUI | 73.4 kBtu/ft² |
| GHG emissions | 784 tCO₂e |
| GHG intensity | 4.4 kgCO₂e/ft² |
| Electricity | 524,194 kWh |
| Natural gas | 3,458 therms |
| Water use | 7,316 kgal |
| Gross floor area | 176,822 sq ft |
| Source record | nyc:21353753:2024 |
The disclosure history
Year over year
| Year | Score | Δ | Site EUI | GHG emissions |
|---|---|---|---|---|
| 2024latest | 78 | +1 | 54.7 kBtu/ft² | 784 tCO₂e |
| 2023 | 77 | +6 | 56.7 kBtu/ft² | 798 tCO₂e |
| 2022 | 71 | 69.5 kBtu/ft² | 909 tCO₂e |
Compliance context
Local Law 84 (LL84)
Under Local Law 97, buildings over 25,000 sq ft face carbon caps with fines of $268 per metric ton of CO₂e over the limit, phasing in from 2024.
Ownership
No owning organisation shown. Names of private individuals in the disclosure are not published here.
Own or manage this building? Claim it to correct the record and get compliance alerts.
Location
- Address
- 300 Willoughby Ave
- City
- New York City
- State
- New York
- ZIP
- 11205
- Coordinates
- 40.69264, -73.95879
Within ~1 km
Nearby benchmarked buildings
- Original Campusscore —
College/University · 1,068,079 sq ft
- LAFAYETTEscore 37
Multifamily Housing · 995,000 sq ft
- 47 Hallscore 100
Multifamily Housing · 584,476 sq ft
- 21 St James Place - 40656score 29
Multifamily Housing · 409,079 sq ft
- 333 Lafayette Ave - 44346score 61
Multifamily Housing · 408,089 sq ft
- 309 Lafayette Avenuescore —
Multifamily Housing · 370,990 sq ft
See also: most efficient in New York City · biggest emitters
How does Benchmarking Group - 119 compare with other K-12 school buildings in New York City?
The latest disclosures cover 2,301 K-12 school buildings in New York City, out of 48,310 buildings citywide. Benchmarking Group - 119's ENERGY STAR score of 78 compares with an average of 64 across the 2,052 that report a score; it scores higher than 63% of them and lower than 36%. Its site EUI of 54.7 kBtu/ft² is about 11% below the average of 61.3 kBtu/ft² — it uses less energy per square foot than the typical building in that group. Its emissions intensity of 4.4 kgCO₂e/ft² is roughly in line with the group average of 4.8 kgCO₂e/ft².
At 176,822 sq ft, it is about 74% above the average floor area of 101,338 sq ft for those buildings. Its 1955 construction date is close to the group's average year built (1954). Across all 24 jurisdictions BuildingCensus covers, the 6,548 K-12 school buildings average an ENERGY STAR score of 64 and a site EUI of 52.7 kBtu/ft².
How has Benchmarking Group - 119's energy performance changed over time?
BuildingCensus holds 3 New York City disclosures for Benchmarking Group - 119, covering report years 2022–2024. Its ENERGY STAR score went from 71 in 2022 to 78 in 2024 (+7 points). Site EUI moved from 69.5 kBtu/ft² (2022) to 54.7 kBtu/ft² (2024), a 21% decrease. Reported emissions went from 909 tCO₂e to 784 tCO₂e over the same span (down 14%).
What does an ENERGY STAR score of 78 mean?
ENERGY STAR scores run from 1 to 100 and are computed by the EPA's Portfolio Manager as a percentile against similar buildings nationwide, adjusted for climate, size and use: a score of 78 means the building performs better than about 78% of its national peers. BuildingCensus bands the score into report-card grades; 78 falls in band B — above median (70–84). Scores of 75 or higher meet the threshold for ENERGY STAR certification; certification itself is a separate, verified application that the disclosure does not record. In New York City, 43% of scored buildings are at 75 or above.
Site energy-use intensity (EUI) is the energy a building uses on site in a year divided by its floor area, in thousand Btu per square foot — lower is more efficient. Benchmarking Group - 119's 54.7 kBtu/ft² across 176,822 sq ft works out to about 9.7 billion Btu (2,835 MWh-equivalent) in 2024. Its source EUI of 73.4 kBtu/ft² also counts the energy lost generating and delivering that power, which is why it is higher. The disclosure also reports 524,194 kWh of electricity, 3,458 therms of natural gas and 7,316 thousand gallons of water for the year.
Which law requires Benchmarking Group - 119 to report its energy use?
Benchmarking Group - 119 reports under Local Law 84 (LL84), the legal basis of New York City's Energy and Water Data Disclosure program, which publishes each covered building's annual benchmarking results. The record shown here is the report-year 2024 disclosure (source record nyc:21353753:2024). Under Local Law 97, buildings over 25,000 sq ft face carbon caps with fines of $268 per metric ton of CO₂e over the limit, phasing in from 2024.
More K-12 school buildings in New York City
- Q072 (OECID: 0400245; BBL: 4124950270)· 176,600 sq ft · score 81 (B)
- DOE_6567_K113· 176,400 sq ft · score 77 (B)
- K314 (OECID: 0301257; BBL: 3008620012)· 176,400 sq ft · score 65 (C)
- X194 (OECID: 0201310; BBL: 2038340070)· 176,400 sq ft · score 42 (D)
- DOE_6571_K117· 176,400 sq ft · score 85 (A)
- 2828 Broadway· 176,125 sq ft · score 69 (C)
- K-12 School buildings in New York City· 2,301 benchmarked
- All New York City benchmarked buildings· Local Law 84 (LL84)
- Most efficient large buildings in New York City
- Least efficient large buildings in New York City
- Biggest emitters in New York City
Frequently asked questions
What is Benchmarking Group - 119's energy grade?
Benchmarking Group - 119 scores 78 out of 100 on ENERGY STAR — band B, above median (70–84) — in its 2024 New York City disclosure. Scores are national percentiles against similar buildings; 75+ qualifies for ENERGY STAR certification.
How much energy does Benchmarking Group - 119 use?
Its 2024 site energy-use intensity was 54.7 kBtu/ft² (73.4 kBtu/ft² source) across 176,822 sq ft, including 524,194 kWh of electricity and 3,458 therms of natural gas.
What are Benchmarking Group - 119's carbon emissions?
Benchmarking Group - 119 reported 784 tCO₂e of greenhouse-gas emissions (4.4 kgCO₂e/ft²) for 2024.
Where is Benchmarking Group - 119?
Benchmarking Group - 119 is at 300 Willoughby Ave, in New York City, New York 11205. Its coordinates are 40.69264, -73.95879 (latitude, longitude), as published in the Energy and Water Data Disclosure file.
How big is Benchmarking Group - 119 and when was it built?
Benchmarking Group - 119 has 176,822 sq ft of gross floor area, as reported in its 2024 disclosure. The disclosure lists 1955 as its year built. It is classed as K-12 school.
Is Benchmarking Group - 119 covered by Local Law 84 (LL84)?
Yes — it appears in the 2024 Energy and Water Data Disclosure disclosure, which lists the buildings reporting under Local Law 84 (LL84).
Working with New York City building benchmarking records? Pro adds alerts, change history and CSV export ($49/mo); Enterprise adds full national files, the API and an MCP server for AI tools.
About this data
Source: Energy and Water Data Disclosure (Local Law 84 (LL84)), as published October 2, 2026. See the methodology for how records are matched, cleaned and scored.
Cite as: BuildingCensus, “Benchmarking Group - 119, New York City, New York — 2024 benchmarking disclosure”, https://buildingcensus.com/buildings/new-york-city/benchmarking-group-119-e2fc1ed8 (data as of October 2, 2026).